Use And Care Manual

6
WIRING
s
!
WARNING Check local electrical and building
codes before installation. The installation must be in accordance with
their regulations as well as the most recent National Electrical
Code (NEC).
Check the pump label for proper voltage required. Do not connect to
voltage other than that shown.
A ground fault circuit interrupter (GFCI) is required.
The pump should be connected or wired to its own circuit, with no
other outlets or equipment in the circuit line. The fuses and circuit
breaker should be of ample capacity in the electrical circuit.
See table below:
Pump HP Votage Breaker Amps
LG-SS100V 1 115 15
s
!
WARNING The flexible jacketed cord assembly
mounted to the pump must not be modified in any way, with the
exception of shortening the cord to fit into a control panel. Any splice
between the pump and the control panel must be made within a
junction box mounted outside of the basin and comply with the
National Electrical Code. Employ a licensed electrician.
s
!
WARNING
Do not use the power cord for lifting the pump.
SPECIFICATIONS
Discharge Size 1-1/2" FNPT
Intake Size 3/4" opening
Pump Housing 300 Series Stainless Steel
Volute Cast Iron
Impeller Cast Iron
Motor
Single-phase permanent split capacitor with automatic reset
thermal overload protection
Hardware Stainless steel
Bearings Ball, top and bottom
Pump Shaft Seal Stationary carbon with Nitrile boot and rotating ceramic seat
Power Cord 18 AWG 3-conductor, copper, stranded, 10' length
Cooling
The motor housing contains oil to cool the motor and to
lubricate bearings and seals. These pumps are capable of
operating with the motor housing partially exposed for
extended periods, providing sucient motor cooling and
bearing lubrication. However, for the best cooling and
longest motor life, the liquid level being pumped should
normally be above the top of the cast iron motor housing.
Ground
Cap
M
115 V Plug
Pump
A-N613
Plug Receptacle
Vertical Switch with
Piggyback Plug
WARNING
WARNING
Electrical Diagrams