Datasheet
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant
257
11
Time–to–Trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00
A
A
B
B
C
D
C
D
Figure T14
TCF250
A = TCF250-180
B = TCF250-145T
C = TCF250-120T
D = TCF250-100T
Time–to–Trip (s)
Fault Current (A)
1000
100
10
1
0.10
0.01
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00
A
A
B
C
D
E
B
C
D
E
Figure T15
TRF250
A = TRF250-180/183/184
B = TRF250-145/145U
C = TRF250-120/120U
D = TRF250-110U/120UT/120T
E = TRF250-080T/080U/080US
Table T4 Dimensions & Weights for PolySwitch Telecommunications and Networking Devices
Cont’d
TS600/TSM600-600V
†
TS600-170F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 23.6
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TS600-200F-RA 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 23.6
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TS600-400F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 19.8
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TSM600-250F 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
TSM600-250F-RA 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
TSM600-400F 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
† 600V
AC
interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Part Number
A
Min Max Figure
Device Mass (g)
(Only for Reference)
B
Min Max
C
Min Max
D
Min Max
E
Min Max
F
Min Max
G
Min Max
Dimensions in Millimeters (Inches)
2013_CP_S11-Poly-8-TeleNetwork.indd 257 8/3/13 10:41 AM