Datasheet
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant
251
11
TS600
TCF250 TRF250 TS250 TSV250 TSL250 TSM600 TRF600
V
MAX
Interrupt (V
AC
)* 250 250 250 250 250 600 600
ITU ITU ITU ITU UL60950 UL60950
GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089
Specification Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 1, 3 and 5 Ports 1, 3 and 5
Hold Current (A)
0.055 — 20.0Ω — — — — —
0.080 — 17.0Ω — — 8.0Ω — —
0.100 11.0Ω — — — — — —
0.110 — 7.0Ω — — — — —
0.120 10.5Ω 8.0Ω — — — — —
0.130 — — 9.0Ω 5.5Ω — — —
0.145 7.0Ω 4.5Ω — — — — —
0.150 — — — — — — 8.0Ω
0.160 — — — — — — 6.0Ω
0.170 — — — — — 11.0Ω —
0.183 — 1.3Ω — — — — —
0.184 — 1.9Ω — 1.6Ω — — —
0.200 — — — — — 8.5Ω —
0.250 — — — — — 3.5Ω 3.0Ω
0.400 — — — — — 1.2Ω 1.2Ω
Voltage Ratings for Telecommunications and Networking Devices
For circuit protection telecommunications devices there are two applicable voltage ratings. These are V
MAX
Operating and
V
MAX
Interrupt. To help understand the nature of these two different voltage ratings, the following definitions are provided:
V
MAX
Operating :
For telecommunications devices, this is the voltage used to obtain component recognition under UL1434. Most circuit
protection devices are certified at 60V but can withstand higher V
MAX
Interrupt conditions.
See Table T3 for its V
MAX
Operating.
*V
MAX
Interrupt : Under specified conditions, this is the highest voltage that can be applied to the device at the maximum current. Devices
may trip safely under higher power level cross conditions, as listed above, to assist equipment in meeting the appropriate
industry conditions.
Table T1
Product Series: Size, Current Rating, Voltage Rating, Typical Resistance for PolySwitch
Telecommunications and Networking Devices
2013_CP_S11-Poly-8-TeleNetwork.indd 251 8/3/13 10:41 AM