Datasheet
RoHS Compliant, ELV Compliant
258
11
Time–to–Trip (s)
Fault Current (A)
1000
100
10
1
0.1
0.01
012 345
67
E
C
B
A
D
E
A
B
C
D
Figure T17
TRF600/TS600/TSM600
A = TRF600-400/TS600-400/
TSM600-400F
B = TRF600-250/TSM600-250F/
TS600-170F/200F
C = TRF600-160
D = TR600-150F-EX
E = TRF600-150
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C)
TCF250*
Terminal Material Nickel-plated Copper Foil
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 1000 hrs
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions
are exceeded.
Physical Characteristics
Environmental Specifications
Table T5
Physical Characteristics and Environmental Specifications for
PolySwitch Telecommunications and Networking Devices
Figures
T14-T17
Typical Time-to-Trip Curves at 20°C for PolySwitch Telecommunications and
Networking Devices
Cont’d
0.00 0.50 1.00 1.50 2.00 2.50 3.00
Time–to–Trip (s)
Fault Current (A)
B
C
D
A
B
D
A
C
Figure T16
TS250/TSV250/TSL250
A = TSV250-184F
B = TSV250-130F
C = TS250-130F
D = TSL250-080F
2013_CP_S11-Poly-8-TeleNetwork.indd 258 8/3/13 10:41 AM