Datasheet

200
RoHS Compliant, ELV Compliant
12
VLR VLP VTP MXP SRP LR4
Hold
Typical ActivationTemperature
Current (A) 85°C 90°C 90°C 120°C 125°C 125°C
1.10 ——16V/0.054 ——
1.20 16V/0.053 ——15V/0.123
1.70 12V/0.025 16V/0.041 ——
1.75 12V/0.024 16V/0.040 16V/0.040 15V/0.070
1.90 ——6V/0.010 15V/0.056
2.00 ——30V/0.045
2.10 16V/0.024 16V/0.024 ——
2.20 16V/0.023 ——
2.30 12V/0.015 ———
2.60 ——15V/0.031
2.70 16V/0.015 ——
3.50 ——30V/0.024
3.70 ——6V/0.013 ——
3.80 ——15V/0.020
4.20 ——30V/0.018
4.50 ——20V/0.016
5.50 ——20V/0.013
6.00 ——20V/0.011
7.30 ——20V/0.009
9.00 ——20V/0.008
13.00 ——20V/0.006
Application Selection Guide for Strap Battery Devices
Mobile phone battery packs Li-ion Surface Mount refer to Surface-mount section of this catalog
Prismatic MXP370BD VLR175F
Cordless phone battery packs NiMH Cylindrical VLP210F ––
SRP175F
Mobile radio battery packs NiMH Cylindrical LR4-380F ––
SRP350F
Computer battery packs NiMH Cylindrical LR4-900F ––
Li-ion Cylindrical LR4-1300SSF ––
Prismatic Consult local Rep Consult local Rep
Camcorder battery packs NiMH or Li-ion Prismatic VLP270F VTP210GF
LR4-380F ––
PDA battery packs Li-ion Prismatic VLP220F VLR175F
Power tools (charge line) NiCd, NiMH or Li-ion Cylindrical custom LR4 custom VTP
Protection Application
PolySwitch Resettable Devices Key Device Selection Criteria
Installation Method Lowest Resistance Lowest Thermal Cut-off
The guide below lists PolySwitch strap battery devices which are typically used in these applications.
The following pages contain the specifications for the part numbers recommended below.
Once a device is selected, the user should evaluate and test each product for its intended application.
Additional Comments
Table B1
Product Series - Current Rating, Voltage Rating / Typical Resistance for
Strap Battery Devices