Datasheet

202
RoHS Compliant, ELV Compliant
12
85°C Typical Activation
VLR*
VLR170F 1.70 4.1 12 100 1.4 8.50 5.0 0.018 0.032 0.064 B3
VLR170LF 1.70 4.1 12 100 1.4 8.50 5.0 0.018 0.032 0.064 B3
VLR170UF 1.70 4.1 12 100 1.4 8.50 5.0 0.018 0.032 0.064 B5
VLR175F 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.031 0.062 B3
VLR175LF 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.031 0.062 B3
VLR175UF 1.75 4.2 12 100 1.4 8.75 5.0 0.017 0.031 0.062 B5
VLR230F 2.30 5.0 12 100 2.5 10.00 5.0 0.012 0.018 0.036 B3
90°C Typical Activation
VLP*
VLP120UF 1.20 3.6 16 60 1.6 7.00 5.0 0.039 0.067 0.134 B5
VLP175UF 1.75 3.9 16 60 1.6 8.75 5.0 0.030 0.050 0.100 B5
VLP210F 2.10 5.0 16 60 1.8 10.50 5.0 0.018 0.030 0.060 B2
VLP220F 2.20 5.3 16 60 1.8 11.00 5.0 0.017 0.029 0.058 B3
VLP270F 2.70 6.5 16 60 2.5 13.50 5.0 0.012 0.018 0.036 B3
VTP*
VTP110F 1.10 2.7 16 100 1.3 5.50 5.0 0.038 0.070 0.140 B5
VTP170F 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B2
VTP170SSF 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B7
VTP170XF 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B3
VTP170XSF 1.70 3.4 16 100 1.4 8.50 5.0 0.030 0.052 0.105 B4
VTP175F 1.75 3.6 16 100 1.4 8.75 5.0 0.029 0.051 0.102 B3
VTP175LF 1.75 3.6 16 100 1.4 8.75 5.0 0.029 0.051 0.102 B3
VTP210GF 2.10 4.7 16 100 1.5 10.00 5.0 0.018 0.030 0.060 B3
VTP210SF 2.10 4.7 16 100 1.5 10.00 5.0 0.018 0.030 0.060 B4
120°C Typical Activation
MXP*
MXP190BB 1.90 4.9 6 50 1.0 9.50 2.0 0.007 0.015 0.024 B12
MXP370BD 3.70 9.0 6 50 1.3 18.50 5.0 0.004 0.010 0.016 B12
* Product electrical characteristics determined at 25°C.
% of Rated Hold andTrip Current
Temperature (˚C)
200
180
160
140
120
100
80
60
40
20
0
-50 -30-40 -10-20 20100 4030 6050 8070 90
A
A
B
C
D
B
C
D
Figure B1
A= LR4
B= SRP
C= VTP, VLP, MXP
D= VLR
Figure B1 Thermal Derating Curve for Strap Battery Devices
Table B3 Electrical Characteristics for Strap Battery Devices
Part
Number
I
H
(A)
I
T
(A)
V
MAX
(V
DC
)
I
MAX
(A)
P
D MAX
(W)
Max.Time-to-trip
(A) (s)
R
MIN
()
R
1MAX
()
Figure for
Dimensions
R
MAX
()