Instruction Manual

341
Revised: 09/23/13
©2013 Littelfuse, Inc
Specifications are subject to change without notice.
Teccor
®
brand Thyristors
Standard Bidirectional SIDACs
Kxxxzy Series
Figure 1: V-I Characteristics
-V
+I
V
DRM
+V
V
S
I
S
I
H
R
S
I
DRM
I
BO
V
BO
V
T
I
T
(I
S
-I
BO
)
(V
BO
-V
S
)
R
S
=
-I
0
1
2
3
4
5
6
7
8
9
0.6 1.0 1.4 1.8 2.2 2.6 3.0 3.4 3.8
Instantaneous On-state Voltage (v
T
) – Volts
n
stantaneous On-state Current (i
T
) – Amps
Kxxx2G
Kxxx0G
Kxxx0E
Kxxx0S
T
J
= 25°C
Figure 2: On-state Current vs. On-state
Voltage (Typical)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE:
See Basic SIDAC Circuit in Figure 12
Kxxx2G
Kxxx0G
Kxxx0E
Kxxx0S
RMS On-State Current [I
T(RMS)
] - Amps
Average On-State Power Dissipation
[P
D(AV)
] - Watts
Figure 3: Power Dissipation vs. On-state Current
(Typical)
Pulse Base Width (t
O
) - us
Repetitive Peak On-State Current (I
TRM
) - Amps
1
10
100
1000
1.0 10.0 100.0 1000.0
5 Hz
60 Hz
5 kHz
120 Hz
1 kHz
di/dt Limit Line
I
TM
t
O
1/f
Figure 4: Repetitive Peak On-state Current (I
TRM
)
vs. Pulse Width at Various Frequencies
1
10
100
1 10 100 1000
Surge Current Duration -- Full Cycles
Peak Surge (Non-repetitive)
On-state Current (I
TSM
) – Amps
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS ON-STATE CURRENT: I
T
RMS Maximum Rated
Value at Specified Junction Temperature
Notes:
1) Blocking capability may be lost during
and immediately following surge
current interval.
2) Overload may not be repeated until
junction temperature has returned
to steady-state rated value.
Figure 5: Peak Non-repetitive Surge Current (I
TSM
)
vs. Number of Cycles
Figure 6: Normalized V
BO
Change vs. Junction
Temperature
-12%
-10%
-8%
-6%
-4%
-2%
0%
2%
4%
-40 -20 0 20 40 60 80 100 120 140
K2xx0E
K2xx0G
K2xx0S
Kxxx2G
K1xx0E
K1xx0G
K1xx0S
V
BO
Change -- %
Junction Temperature (T
J