Cut Sheet

© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/
Rev: 1-A-062716
Protection Relays
Current Monitoring Relays and Transducers
Current measuring
device
Voltage measuring
device
LCSC10T12
Current Sensor
Connection for
4-20mA Loop
To LCSC10T12
Current Sensor
Jumper used when
current source is not
LCSC10T12
Connection for
Analog Voltage Output
Connect One:
V
DA
= 1 to 5VDC
V
DB
= 2 to 10VDC
C
D
A
B
249Ω
249Ω
DCSA
A
D = Instrument, meter or PLC input
PS = Power Supply
LCSC10T12
Current Sensor
Connect One:
A = 1 to 5VDC
B = 2 to 10VDC
DCSA 50
AD = Instrument, Meter,
or PLC Input
PS = Power Supply
www.littelfuse.com/dcsa
DCSA SERIES
Description
The DCSA Series is a loop-powered, linear output current
transducer that provides an output that is directly proportional to
the RMS AC current passing through the LCSC10T12 sensor. The
DCSA Series provides either an analog current or voltage: 4-20
mA, 1 to 5VDC, or 2 to 10VDC. Each unit is factory calibrated
for monitoring (with the LCSC10T12 connected) in one of four
ranges; 0-5, 0-10, 0-20, or 0-50A. Zero and span adjustments
allow field calibration if needed. The DCSA Series mounts on
both DIN 1 and DIN 3 rails.
Operation
The DCSA Series varies the effective resistance of its output
in direct proportion to the current flowing in the conductor
monitored by the LCSC10T12. Connecting the power supply to
terminals C & D provides a 4 to 20mA DC current. Connect the
power supply to terminals C & A to get 1 to 5VDC at terminal D.
Connect the power supply to terminals C & B to get 2 to 10VDC
at terminal D.
Features
Mounts on DIN 1 or DIN 3 rail
0-50A in 4 ranges using LCSC10T12 sensor
Loop powered from 10 to 30VDC
Linear output from 4-20mA, 1-10VDC
Zero & span adjustments
Separate sensor & control unit
Accessories
LCSC10T12 Toroidal Current Sensor
Remote monitoring of currents up to 50A.
Wiring Diagram
Current Transducers
CONNECTION FOR 4 - 20 MA LOOP
To LCSC10T12 Current Sensor
Current measuring
device
Voltage measuring
device
LCSC10T12
Current Sensor
Connection for
4-20mA Loop
To LCSC10T12
Current Sensor
Jumper used when
current source is not
LCSC10T12
Connection for
Analog Voltage Output
Connect One:
V
DA
= 1 to 5VDC
V
DB
= 2 to 10VDC
C
D
A
B
249Ω
249Ω
DCSA
A
D = Instrument, meter or PLC input
PS = Power Supply
Connect One:
A = 1 to 5VDC
B = 2 to 10VDC
Jumper used when current
source is not LCSC10T12
CONNECTION FOR ANALOG
VOLTAGE OUTPUT
DCSA 50
AD = Instrument, Meter,
or PLC Input
PS = Power Supply
Ordering Information
MODEL
CURRENT RANGE WITH
LCSC10T12
INPUT RANGE (F TO E)
DCSA5 0-5A 0-5mA AC
DCSA20 0-20A 0-20mA AC
DCSA50 0-50A 0-50mA AC