Installation Instructions
STEP-BY-STEP GUIDE
Page 3
Trouble Shooting Guide
If this fi xture fails to operate properly, use the guide
below to diagnose and correct the problem.
Verify that fi xture is wired properly.
Verify that fi xture is grounded correctly.
Verify that the line voltage at the fi xture is correct.
If further assistance is required, contact:
Technical Support at: (800) 748-5070
This LED module does not require service or new bulbs to
change.
Note: Before beginning the installation, make sure all power is off,
shutting power off in breaker box to areas where downlights are to be
installed is recommended.
Required Tools (not included): Safety glasses and gloves.
1. Double check and measure the ceiling hole. Make sure it is the
correct size for outside rim of the luminaire to cover the hole while still
allowing the back of luminaire to sink in to the ceiling and springs to
hold fi rmly.
Remove existing retrofi t can if present or move it out of the way
since it will not be needed for installation.
If new hole is to be cut, use provided hole template. Place
template over the desired location. Trace the outer ring with a pen
or pencil (not included). Cut the opening with a saw (not included).
(Figure 1)
2. Open the cover of the remote driver box. Push and remove one of
the knockouts on the side plate.
Locate power supply leads from remote driver box and connect to
power source using connectors (provided).
Connect black wire to live wire, white wire to neutral wire, and cop-
per wire with ground (as shown) and secure using connector. Close
the cover of the box. (Figure 2)
3. Connect the remote driver box to the light fi xture and tighten the
nut connector by hand. Arrow on the male and female parts of the con-
nector between the driver and fi xture cable should match. (Figure 3)
4. Place remote driver box thru the cut-out hole. If remote driver
box need to be attached, use provided keyhole fi ttings on the back of
the box to hang it using round head screw (not included). (Figure 4)
Figure 1 / Figura 1 / Schéma 1
5. Pull the spring clip on the fi xture up and through the ceiling
hole and place module in the hole making sure the spring clips are
holding securely. (Figure 5)
6. Turn the power back on. If the module doesn’t illuminate within
5 seconds, turn power off, carefully remove the module and double
check all wiring. (Figure 6)
WARNING:
DO NOT PLACE YOUR HAND UNDERNEATH SPRING CLIP
DURING REMOVAL PROCESS. SNAPPING OF THE CLIPS CAN
CAUSE INJURIES TO THE HAND. (Figure 7)
DO NOT USE ANY OTHER DRIVER EXCEPT LITHONIA
LIGHTING DRIVER THAT IS INCLUDED WITH THE FITURE.
DO NOT CONNECT MULTIPLE MODULES TO ONE DRIVER.
DO NOT OPEN THE MODULE AND SIDE PLATE OF THE
REMOTE DRIVER BOX - NO SERVICEABLE PARTS INSIDE.
Figure 6 / Figura 6 / Schéma 6
Figure 3 / Figura 3 / Schéma 3
THREAD
LOCK
Figure 7 / Figura 7 / Schéma 7
DO NOT
DO NOT
PLACE YOUR
PLACE YOUR
HAND
HAND
DO NOT
DO NOT
PLACE YOUR
PLACE YOUR
HAND
HAND
Figure 5 / Figura 5 / Schéma 5Figure 4 / Figura 4 / Schéma 4
Figure 2 / Figura 2 / Schéma 2
ACCESS
NEUTRAL WIRE
(FROM POWER SUPPLY)
GROUND WIRE
(FROM POWER SUPPLY)
LIVE WIRE
(FROM POWER SUPPLY)
NEUTRAL WIRE
GROUND WIRE
LIVE WIRE
NEUTRAL
WIRE
(WHITE)
GROUND
WIRE
(BARE COPPER /
GREEN)
LIVE
WIRE
(BLACK)
(FROM POWER SUPPLY)
(FROM DRIVER BOX)
connector
connector
connector
THROUGH
CEILING
HOLE
PULL UP
SIDE WALL
ATTACH USING PROVIDED
KEYHOLE FITTINGS
(MOUNTING