Cut Sheet
Fluorescent
FEATURES & SPECIFICATIONS
INTENDED USE
Ideal where high brightness and high illumination levels are required such
as retail, industrial and warehouse applications.
ATTRIBUTES
Fixtures assembled with snap and screwed together components. Avail-
able in a variety of lengths and lamp configurations. Gripper-back design for
superior strength and rigidity.
CONSTRUCTION
Heavy-duty, 20-guage channel, cold-rolled steel.
Sturdy channel cover secured by quarter-turn latch for tool-less access to
wireway. Screw-on endplates.
FINISH
Five-stage iron-phosphate pretreatment ensures superior paint adhesion
and rust resistance. Finish is high-gloss baked white polyester.
ELECTRICAL SYSTEM
Thermally protected, resetting, Class P, HPF, UL listed, CSA Certified ballast is
standard. Magnetic ballast complies with ballast efficiency requirements of
U.S. Department of Energy 10CFR Part 430. Ballasts for T12HO rated to start
full-wattage lamps at -20°F. CW20 cold-weather option will appear in fixture
description.
Fixture is suitable for damp locations. AWM, TFN or THHN wire used through-
out, rated for required temperatures.
INSTALLATION
For unit or row installation, suspended mounting. Channel connector fur-
nished standard.
LISTING
UL Listed to US and Canadian safety standards. Optional: Mexico NOM.
WARRANTY
Guaranteed for one year against mechanical defects in manufacture.
Sheet #: UND-Mag STRP-310
All dimensions are inches (millimeters) .
Specifications subject to change without
notice.
Specifications
Length: 24" (610), 36" (914), 48" (1219),
72" (1829) or 96" (2438)
Width: 4-3/8" (124)
Height: T12 3-11/16" (94)
Heavy-Duty Strip
UND
T12, MAGNETIC BALLASTS
4', 6' or 8' length
1 or 2 lamps
Catalog Number
Notes Type
Voltage
120
277
347
Lamps
1
1
2
Not included.
Options
Shipped installed in fixture
CW20 Cold-weather ballast -20°F starting
MBX U.S. Department of Energy compli-
ant magnetic ballast
EL14 Emergency battery pack (nominal
1400 lumens), see Life Safety Section
GLR Internal fast-blow fusing
GMF Internal slow-blow fusing
PLF_ Plug-in wiring; specify 1, 2 or 3 branch
circuits and hot wires (A=black,
B=red, C=blue, AB or AC)
TILW Tandem in-line wiring
NOM NOM Certified
Series
UND Heavy-duty
channel for
T12 lamps
For tandem double-
length unit, add prefix T.
Example: TUNS
Accessories
Order as separate catalog numbers.
SQ_ Swivel stem hanger (specify length in 2" increments)
1B Ceiling spacer (1-1/2" to 2-1/2" from ceiling)
HC36 Chain hangers (1 pair, 36" long)
THUN Tong hanger
HRUND1 Hooker® T-bar hanger (1-1/2" from ceiling), UND only
CSMR48 Symmetric reflector, 4' white
CASR48 Asymmetric reflector 4' white
WGCUN Wireguard, 4' white
2
NOTES:
1 Not available with 347V.
2 Order two for 8' fixtures. For strip channels only.
Lamp type
48HO 60W T12 800MA (48")
1
72HO 85W T12 800MA (72")
96HO 110W T12 800MA (96")
For shortest lead times, configure product using standard options (shown in bold).
Example: UND 2 96HO 120 CW20 MBX
ORDERING INFORMATION
UND