Installation Instructions
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-479 Rev A
Revision Date: 8/28/19
5. Insert the ground wire from tenon to the 3-way wire nut with the green wires from SPD and luminaire ground connecon
and lock it. Repeat this step for black (hot) and white (neutral) wires. Select matching colored wires coming from SPD (See
Figure 9a, 9b, 9c).
6. Use cable e and bundle all newly aached wires as
shown in Figure 10.
7. Make sure that wires and door tethers are not pinched
and that the door gasket is sll snugly in its groove on the
door. Reinstall the mounng door (Fig 11) that was re-
moved, ghten the six capve screws with the 5/32 Allen
wrench to 25-30 in-lbs (overghtening can cause thread
stripping and void all warranes).
Page #6