RSX LED
RSX SPA/RPA & ESPA/ERPA INSTALLATION INSTRUCTION
Tools Required:
• 3/8" Socket Wrench
• 9/64” Allen Wrench
Minimum Square Pole: 3.5” Face
Minimum Round Pole: 3.2” Diameter
1. Loosen the capve screws of the arm cover (Fig 1) to
access the pole mounng area
2. Two mounng bars are included in the installaon kit:
a. The shorter bar is used for #8 Lithonia drilling paern
and has 3 holes. The top and boom hole are threaded.
b. The longer bar has one top hole and a slot with a slid-
ing threaded hole to be used on poles with exisng drill pat-
terns.
3. If the bar with the #8 drilling paern
(Fig 2a) does not line up with exisng holes,
use the universal mounng bar (Fig 2b) with
the sliding thread.
Insert one of the included 3/8 mounng
bolts through the top hole of the pole and
thread into the mounng bar. For a round
pole, the round pole adapter (RPA) is re-
quired and must be placed between the pole
and the xture as shown with the curved
side contacng pole and at side facing away
from pole (Fig 2c).