Technical Specifications

2 of 2
Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com © 2014-2015 Acuity Brands Lighting, Inc. All rights reserved. 07/29/15
WIRING (DO NOT WIRE HOT)
PTS - TS-PTS-001A
STANDARD WIRING
BLACK* - Line Input
BLACK* - Load Output
GREEN SCREW - Ground (required connection)
347 VAC OPTION (347)
Black wires are replaced w/ Red wires
PROGRAMMING INSTRUCTIONS
(PLEASE READ ALL 7 STEPS BEFORE PROGRAMMING)
1. Enter programming mode by pressing & holding upper left button until LED flashes rapidly. Release button.
2. Enter a specific programming function by pressing button the number of times as the desired function number from the
tables on the following pages (e.g., for a PTS 60, press five times for function 5, Max Time Allowable).
3. The selected function’s current setting will then be read out in a sequence of LED flashes (e.g., one flash for 60 min). To
change setting, proceed to step 4 before sequence repeats 10 times.
4. While the switch is flashing back current setting, interrupt it by pressing button the number of times for the new desired
setting as indicated in the particular function’s detailed table (e.g., press twice for 30 min). Switch will begin to flash new
setting as confirmation.
5. Next, while the switch is flashing back new setting, interrupt it by pressing and holding button until LED flashes rapidly.
Release button.
6. As final confirmation and activation of the new setting, re-enter the programming function number that was changed (e.g.,
press five times for function 5, Max Time Allowable).
7. LED will flash twice indicating acceptance of new setting. If two flashes are not seen, repeat 7 step process.
Note: To exit programming mode without saving or to change to a different function, wait for blink back sequence to repeat 10
times then return to step 1.
Function
Number
Function
Name
Settings (*indicates default setting)
2 Blink Warning
1. Enabled 2 min & 1 min* 3. Enabled 1 min
2. Disabled 4. Enabled 2 min
3 Beep Warning 1. Enabled* 2. Disabled
4 Status Tick 1. Enabled
(ticks every 1 sec)
2. Disabled* 3. Enabled,
(ticks every 0.5 sec)
5
Max Time Allowable
(model # PTS 60)
1. 60 min* 3. 15 min 5. 5 min
2. 30 min 4. 10 min 6. 2 min
5
Max Time Allowable
(model # PTS 720)
1. 12 hr* 3. 4 hr 5. 60 min
2. 8 hr 4. 2 hr 6. 30 min
6
Default Time - when on/off button
pressed
(model # PTS 60)
1. 60 min 4. 10 min 7. Last time selected*
2. 30 min 5. 5 min
3. 15 min 6. 2 min
6
Default Time - when on/off button
pressed
(model # PTS 720)
1. 12 hr 4. 2 hr 7. Last time selected*
2. 8 hr 5. 60 min
3. 4 hr 6. 30 min
9 Factory Defaults 1. Maintain current* 2. Restore defaults