Specifications

Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be
representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance
data on any configurations not shown here.
To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s OFL Series Flood Size 1 homepage.
Performance Package System Watts Dist. Type
Field Angle Beam Angle 40K 50K
°H °V °H °V Lumens LPW Lumens LPW
P1 23W WFL
106 106 71 72 2,071 90 2,137 91
P2 49W WFL
106 106 71 72 3,963 81 3,979 81
Performance Data
Photometric Diagrams
One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com
© 2012-2016 Acuity Brands Lighting, Inc. All rights reserved.
Lumen Output
Current (A)
Power
Package
S
ystem
Watts
120V 208V 240V 277V 347V
P1 23W
0.21 0.12 0.11 0.1
-
P2 49W
0.41 0.24 0.2 0.19
-
Electrical Load
Use these factors to determine relative lumen output for
average ambient temperatures from 0-40°C (32-104°F).
Lumen Ambient Temperature
(LAT) Multipliers
Ambient Lumen Multiplier
0°C 32°F 1.06
10°C 50°F 1.03
20°C 68°F 1.01
25°C 77°F 1.00
30°C 86°F 0.99
40°C 104°F 0.97
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for
the OFL Flood Size 1 platform based on 9000 hours of LED
testing (tested per IESNA LM-80-08 and projected per IESNA
TM-21-11).
To calculate LLF, use the lumen maintenance factor that
corresponds to the desired number of operating hours below.
For other lumen maintenance values, contact factory.
Operating Hours 0 25,000 50,000
Lumen Maintenance
Factor
1 0.88 0.78
Mounting, Options and Accessories
THK- Knuckle with 1/2” NPS
threaded pipe
YK- Yoke mount Slipfitter attachment
DSXF1/2 TS
Wire Guard
OFL1WG
Vandal Guard
(Polycarbonate lens)
OFL1VG
OFL1 LED
Rev. 8/16/16