FIGURE 4: TO SEMI-FLUSH MOUNT FIXTURE
Follow steps 5B to 11B.
5B. Gather the black, white and bare ground fixture wires
together and feed them through the center of the spacer
canopy unitl the lower canopy rests on the pan.
See Figure 1.
6B. Insert (2) #8-32 x 1" machine screws through pan and
lower canopy. Thread a ball finial onto each screw to secure
the spacer canopy. See Figure 1.
7B. With the power off, hold the fixture firmly and connect the
ground wire from the fixture to the junction box, by wrapping
them under the head of the green ground screw and secur-
ing them to the crossbar. (If house wiring includes no ground
wire consult your local electrical code for approved meth-
ods). See Figure 5.
8B. Use wirenuts to connect the black fixture wire(s) to the
black power supply wire and white fixture wire(s) to white
power supply wire. See Figure 5 .
FOR PROPER CONNECTION, PLACE WIRENUT OVER
WIRES, TWIST CLOCKWISE UNTIL TIGHT.
9B. Align the holes in the upper canopy with the screws ex-
tending from the cross bar previously mounted to the junction
box. See Figure 5.
10B. Hold the canopy against the ceiling and thread a ball
finial onto each screw until canopy is secure. See Figure 5.
11.Insert lamps and reinstall diffuser by aligning glass with
pan and twist clockwise to tigthen. See Figure 1.
12. Turn on electricity at fuse or circuit breaker box .
WIRING AND FIXTURE OPERATION
CAUTION: Connect fixture to supply wires rated for at least 90°
(194°F). Do not use fixture on dimming circuits.
Figure 5