Installation Instructions
Page 5 of 9
U4118 Rev A
LED IMPORTANT SAFETY INSTRUCTIONS
SECTION D: INSTALLATION - SUSPENDED FIXTURE
1) If using the V-hanger and chain, feed hanger through chain link.
2) If using the HC V-Hanger (supplied with HC36 and ZACVH), hook the hanger through holes in the electrical channel shown
below.
3) Secure the other end of the chain to a structure using hardware rated for the load. Contact factory or agency for areas that
have vibration, overhead cranes and/or high velocity
Make sure the wiring hangers are fully engaged into the side holes on the electrical channel. If using "S" hooks, make sure all
loops are crimped closed if possible. Make sure wire hanger fit snuggly into side hole of driver channel.
4) Remove access plate screw as shown above. Input wires will be attached to the access plate. Remove the necessary knockout(s)
and connect input wires black to black, white to white and green to green. Use only UL listed connectors rated 90C or greater.
Purple and Gray wires are low voltage dimming leads.
5) Make any necessary electrical connections. Supply wire must meet applicable electrical codes and be rated for a minimum of
90⁰C. Purple and gray leads are 0-10V (low voltage) dimming leads.
Required Mounting Holes for
HC V-hanger (supplied with
HC36 and ZACVH)
Access Plate Screw