Specification

Catalog
Number
Notes
Type
Compact Fluorescent Downlighting
6" LF6N
OPEN REFLECTOR
Horizontal, 2-Lamp Double Twin-Tube (DTT)
Specifications
Max. height: 6-3/8 (16.2)
Ceiling opening: 7 (17.8)
Overlap trim: 7-1/2 (19.1)
Length: 13 (33.0)
Width: 11 (27.9)
All dimensions are inches (centimeters) unless otherwise indicated.
FEATURES & SPECIFICATIONS
INTENDED USE — Ideal for a wide variety of low- to medium-height ceiling applications including
commercial, retail and hospitality spaces where an open or damp location lensed xture is required.
CONSTRUCTION — Heavy gauge die formed galvanized steel mounting frame with mechanical
trim retention (yoke) ensures secure and ush reector mounting to ceiling. Attached to frame are
vertically adjustable mounting brackets for use with C channels, ½” steel conduit or 16 gauge at bar
hangers included, standard. Frames equipped with galvanized junction box UL Listed for through wire
applications. Junction boxes equipped with (2) ¾” and (4) ½” conduit knockouts with pryout slots and
removable access doors.
Maximum 1-1/2” ceiling thickness.
OPTICS — Aluminum full reectors are optically designed to maximize lumen output and to provide
superior glare control. Anodized nishes for open reectors are semi-specular or diuse in a variety of
colors. Polyester powder coat nishes also are available in white.
Lenses are available in clear at glass, tempered prismatic glass, or polycarbonate to provide optimal
visual comfort and improved aesthetics. Lens is recessed 1-1/2 (3.8) from ange.
ELECTRICAL — Electronic ballast with end of lamp life protection standard. Class P thermally protected
ballast protects against improper contact with insulation. Minimum starting temperature is 0°F/-18°C.
Rated for #12 AWG conductor thru-branch wiring. Minimum 90° supply wire.
Ground wire provided.
Lamp Socket Base:
DTT 4-pin lamps – 13W (G24Q-1); 18W (G24Q-2); 26W (G24Q-3)
LISTINGS — Fixtures are UL Listed for thru-branch wiring, Non-IC recessed mounting, damp location,
and to U.S. and Canadian Safety Standards.
Note: Specications subject to change without notice.
Notes
1 Not available with ADEZ or ECOS.
2 Not available with CGL, T73 and PCL lens.
3 Electronic multi-volt ballast capable of operating any line voltage from 120-277V, 50 or 60Hz.
4 Not available with EL or ELR.
5 For additional options see www.lithonia.com.
6 Ships standard for 1-lamp operation. For 2-lamp operation, consult installation instructions or factory. Add 3”
(7.6) to width and 4-1/2” (11.4) to length.
7 Not recommended for eld installation.
8 One 5A relay with one 0-10 VDC dimming output, shipped installed. Requires additional nLight bus power supply.
DOWNLIGHTING LF6N-OPEN-2-DTT
Accessories: Order as separate catalog number.
SCA6 Sloped ceiling adaptor. Degree of slope must be
specied (10D, 15D, 20D, 25D, 30D) Ex: SCA6 10D.
CTE6 Ceiling thickness extender is used when ceiling
thickness is greater than 1-1/2 (3.8). Maximum
thickness 2 (5.1).
LF6N
Series Wattage/Lamp Reector/Color Lens type Voltage Options
5
LF6N 2/13DTT
1
2/18DTT
2/26DTT
F6O2 White open
F6O2A Clear diuse open
F6O2AZ Clear semi-specular
open
F6O2G Gold diuse open
F6O2GZ Gold semi-specular
open
F6O2PR Pewter diuse open
F6O2WTZ Wheat semi-specular
open
F6C3BLZ Black specular open
cone
2
(blank) No lens
CGL Clear glass lens
T73 Tempered glass
prismatic lens
PCL Clear polycarbonate
lens
MVOLT
3
120
277
347
4
ADEZ Advance Mark 10™ electronic dimming ballast, 120V or 277V. Must be
wattage and voltage specic. Minimum dimming level 5%
ECOS Lutron EcoSystem electronic dimming ballast, 120V - 277V. Must be
wattage specic. Minimum dimming level 5%
EL Emergency PSDL3 DL battery pack with integral test switch. Lens
removal required before EL testing
6
ELR Emergency PSDL3 DL battery pack with remote test switch
6
ELRHL2LP Iota I-162 Emergency battery pack with remote test switch. Operates
two 26W CFL lamps in emergency mode with battery back-up in case of
power disruption. Average lumen output is 2600
7
GMF Single slow-blow fuse, must specify voltage
BDP Ballast disconnect plug (meets codes that require in-xture disconnect)
4
RIF1 Radio interference lter
LBH Less barhangers
WLP 35K lamp (shipped separately)
NSD Sensor Switch nLight™ dimming relay
8
TRW White ange
ORDERING INFORMATION
For shortest lead times, congure product using bolded options.
Example: LF6N 2/26DTT F6O2AZ MVOLT
6-3/8
(16.2)
7-1/2
(19.1)
11
(27.9)
13
(33.0)
6-3/8
(16.2)
6-1/8
(15.6)
7-1/2
(19.1)

Summary of content (2 pages)