Specification

SPECIFICATIONS
ELECTRICAL
Primary Circuit
Supply voltage AC input watts Max. amps VA
120 5.8 .052 6.2
277 5.9 .023 6.4
BATTERY
Sealed Lead-Calcium
Voltage
Shelf
life
1
Typical
life
1
Maintenance
2
Optimum
temperature
3
6 12 Months 5–7 years none 60° - 90°F (16° - 32°C)
ELRG Emergency Recessed Gimbal
Notes
1 At 77°F (25°C).
2 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and
tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the
required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties.
3 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower
temperatures aect life and capacity. Consult factory for detailed information.
9
(22.9)
8-1/2
(21.6)
14 to 24
(35.6 to 61.0)
7
(17.8)
7-5/8
(19.3)
6
(15.2)
4-1/2
(11.4)
ELRG
6-volts, 8 watts, halogen
HORIZONTAL
1 0.5 0.3
4
2
0
2
4
VERTICAL
1 0.5 0.3
4
2
0
2
4
10 20 30 Ft.
Replacement Lamp # 785
PHOTOMETRICS
DIMENSIONS
All dimensions are inches (centimeters).
Weight: 6.5 lbs (3 kgs)
Ceiling opening dia.: 6 (15.2)
ELRG