Specification
To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Flood Size 3 homepage.
One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • Fax: 770.918.1209 • www.lithonia.com
© 2011-2016 Acuity Brands Lighting, Inc. All rights reserved.
DSXF3-LED
Rev. 02/18/16
Page 2 of 3
Photometric Diagrams
Isocandela plots for the DSXF3 LED 6 P2 40K. Distances are in units of mount height (20ft).
LEGEND
(% Max cd)
10%
20%
30%
40%
50%
60%
75%
90%
Test No. 8408P4 tested in accordance with
IESNA LM-79-08.
Test No. 8414P4 tested in accordance with
IESNA LM-79-08.
Test No. 8405P4 tested in accordance with
IESNA LM-79-08.
Test No. LTL29249P4 tested in accordance
with IESNA LM-79-08.
Test No. 8409P4 tested in accordance with
IESNA LM-79-08.
Test No. 8414P4 tested in accordance with
IESNA LM-79-08.
Test No. 8414P4 tested in accordance with
IESNA LM-79-08.
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
NSP
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
WFL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
MFL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
HMF
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
MSP
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
WFR
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
FL
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown,
within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here.
Light
Engines
Performance
Package
System
Watts
Dist.
Type
Field
Angle
Beam
Angle
30K
(3000 K, 70 CRI)
40K
(4000 K, 70 CRI)
50K
(5000 K, 70 CRI)
°H °V °H °V Max Cd Lumens LPW Max Cd Lumens LPW Max Cd Lumens LPW
6
P1 129
NSP
38 35 18 18 84476 13510 105 88800 14201 110 88800 14201 110
MSP
53 52 27 27 49237 12774 99 51757 13428 104 51757 13428 104
MFL
59 59 45 45 22746 12986 101 23911 13650 106 23911 13650 106
FL
84 90 61 71 11658 13952 108 12255 14666 114 12255 14666 114
WFL
104 105 73 76 9435 14454 112 9918 15194 118 9918 15194 118
WFR
104 91 80 72 9546 14377 111 10035 15113 117 10035 15113 117
HMF
121 67 94 55 10455 13238 103 10991 13916 108 10991 13916 108
P2 183
NSP
38 35 18 18 105595 16887 92 111000 17751 97 111000 17751 97
MSP
53 52 27 27 61546 15968 87 64696 16785 92 64696 16785 92
MFL
59 59 45 45 28433 16232 89 29888 17063 93 29888 17063 93
FL
84 90 61 71 14573 17440 95 15319 18333 100 15319 18333 100
WFL
104 105 73 76 11794 18067 99 12397 18992 104 12397 18992 104
WFR
104 91 80 72 11933 17972 98 12543 18891 103 12543 18891 103
HMF
121 67 94 55 13069 16548 90 13738 17395 95 13738 17395 95
Performance Data
Lumen Output
Current (A)
Performance
Package
System
Watts
120V 208V 240V 277V 347V 480V
P1
129 1.08 0.62 0.54 0.47 0.38
0.29
P2
183 1.54 0.87 0.75 0.65 0.53
0.40
Electrical Load
Use these factors to determine relative lumen output for
average ambient temperatures from 0-35°C (32-95°F).
Lumen Ambient Temperature
(LAT) Multipliers
Ambient Lumen Multiplier
0°C 32°F 1.08
0°C 50°F 1.05
20°C 68°F 1.02
25°C 77°F 1.00
30°C 86°F 0.98
35°C 95°F 0.96
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for
the DSXF3 LED 6 P2 platform based on 13,000 hours of LED
testing (tested per IESNA LM-80-08 and projected per IESNA
TM-21-11).
To calculate LLF, use the lumen maintenance factor that
corresponds to the desired number of operating hours below.
For other lumen maintenance values, contact factory.
Operating Hours 0 25,000 50,000 100,000
Lumen Maintenance
Factor
1.0 0.97 0.97 0.96