Instructions / Assembly

Part Number: RJ521391 Rev B
Revision Date: 9/22/15
Installation Instructions
DSXF LED
Troubleshooting: If this xture fails to operate properly, check to make sure: • The xture is wired correctly. • The xture is grounded cor-
rectly. • The line voltage at the xture is correct. If all these variables have been checked and the xture still does not operate as specied,
contact your local Lithonia Lighting distributor.
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 • www.lithonia.com
© 2012 Acuity Brands Lighting, Inc. All rights reserved.
UBV
UPPER or BOTTOM
VISOR
FV
FULL VISOR
VG
VANDAL
GUARD
WG
WIRE GUARD
(DSXF3 only)
N/A
N/A
DSXF3 WG
DSXF3 UV or BV DSXF3 FV
DSXF3 VG
DSXF2 UV or BV
DSXF2 FV DSXF2 VG
DSXF1 UV or BV
DSXF1 FV
DSXF1 VG
Integral Slipfitter Mount (IS): DSXF1 or DSXF2 (ships in fixture carton): Remove parts from carton: (1) fixture, (1) slipfitter, (1) hardware bag with
quantity 1-gasket, and 4-screws. Place the gasket onto xture bottom. Place sliptter against gasket and attach with 4 screws. To adjust the tilt
angle of the xture, loosen the 3/16” hex key screw. Adjust as necessary and retighten. Supply leads exit through the center of the sliptter to
make connections in wiring compartment (not provided). Secure to the top end of a 1-1/4” to 2” pipe by tightening set screws to 12 ft.-lbs.
DSXF3 (ships installed): Remove the access cover plate to the integral wiring compartment using a 1/4" hex socket or regular screwdriver. Slip
integral slipfitter onto tenon ensuring that the wires are pulled through the integral wiring compartment without pinching. Secure the slipfitter
to the tenon by tightening the 3/16” hex socket set screws. To adjust the tilt angle of the xture, loosen the 5/16” hex socket screw above the
integral wiring compartment. Adjust as necessary and retighten. Make supply connections through the integral wiring compartment. Push wires
into compartment. Re-install the access cover plate.
DSXF1 (integral slipfitter) DSXF2 (integral slipfitter) DSXF3 (integral slipfitter)
Shielding Options: The doorframe can be opened with any of the
shielding options attached. Attach with the 8-32 thread forming
screws provided. Holes will be provided in the doorframe. Should
the doorframe holes need be cleared for any reason, drill no
deeper than 1/4" with a .147" (#26) diameter drill.
Tenon Slipfitter (DSXF1/2TS) Installation
(for use with THK mounting option):
Attach DSXF1/2TS to xture’s threaded 1/2" knuckle. Secure to
the top end of 1-1/4” to 2” pipe by tightening set screws to 12
ft.-lbs and lock down with jam nuts.
1/2-14 NPS
5/16-18 NPT
(3 places)
3-7/16"
2-1/2"