Specification
To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Flood Size 2 homepage.
Photometric Diagrams
One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • Fax: 770.918.1209 • www.lithonia.com
© 2012-2014 Acuity Brands Lighting, Inc. All rights reserved.
Isocandela plots for the DSXF2 LED 4 A530/40K.
LEGEND
(% Max cd)
10%
20%
30%
40%
50%
60%
75%
90%
Test No. LTL22174P6 tested in accordance
with IESNA LM-79-08.
Test No. LTL22173P6 tested in accordance
with IESNA LM-79-08.
Test No. LTL22153P6 tested in accordance
with IESNA LM-79-08.
Test No. LTL22159P6 tested in accordance
with IESNA LM-79-08.
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
MSP
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
WFL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
FL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
HMF
Mounting, Options and Accessories
THK - Knuckle with
1/2” NPS threaded pipe
IS – Integral sliptter
H= 2-1/2” (6.3 cm)
ID= 2-3/8” (6.0 cm)
OD= 3-1/2” (8.8 cm)
UBV – Upper/bottom visor
W= 10” (25.4 cm)
H= 2-1/2” (6.3 cm)
D= 3” (7.6 cm)
FV – Full visor
W= 10” (25.4 cm)
H= 2-1/2” (6.3 cm)
D= 3” (7.6 cm)
YKC62 - Yoke with SO cord
W= 4-3/4” (12.0 cm)
H= 4-1/4” (10.7 cm)
D= 2-1/4” (5.7 cm)
H
ID
OD
W
D
W
D
W
H
H
VG – Vandal guard
W= 10-1/2” (26.6cm)
H= 4“ (10.1cm
W
H
D
H
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown,
within the tolerances allowed by Lighting Facts. Actual performance may differ as a result of
end-user environment and application. Actual wattage may differ by +/- 8% when operating between 120-480V +/- 10%. Contact factory for performance data
on any configurations not shown here.
Light
Engines
Drive
Current
(mA)
Performance
Package
System
Watts
Dist.
Type
Field
Angle
Beam
Angle
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
°H °V °H °V Max Cd Lumens LPW Max Cd Lumens LPW Max Cd Lumens LPW
3 530 A530/--K 54W
NSP
48 49 19 19 19,398 3868 72 20,166 4648 86 20,103 4670 86
MSP
50 48 24 23 18,631 4234 78 18,619 5087 94 18,561 5111 95
MFL
60 60 47 46 6177 3614 67 7751 4342 80 7726 4363 81
FL
85 84 63 62 5069 4813 89 5124 5783 107 5108 5810 108
WFL
106 106 71 72 3573 4776 88 3842 6108 113 3830 5766 107
WFR
107 88 85 64 3513 4845 90 3828 5821 108 3816 5849 108
HMF
100 62 80 13 3969 2119 39 3479 2546 47 3468 2558 47
4 530 A530/--K 74W
NSP
48 49 19 19 25,870 5159 70 26,893 6198 84 26,809 6228 84
MSP
50 48 24 23 25,415 5775 78 24,830 6933 94 24,752 6966 94
MFL
60 60 47 46 8237 4820 65 10,336 5791 78 10,304 5818 79
FL
85 84 63 62 6760 6419 87 6833 7712 104 6811 7749 105
WFL
106 106 71 72 4758 6359 86 5124 7633 103 5108 7670 104
WFR
107 88 85 64 4684 6462 87 5105 7764 105 5089 7801 105
HMF
100 62 80 13 5293 2826 38 4639 3396 46 4625 3412 46
Performance Data
Lumen Output
Current (A)
Light
Engines
Drive
Current (mA)
System
Watts
120 208 240 277 347 480
3 530 54W 0.47 0.28 0.22 0.2 0.17 0.12
4 530 74W 0.63 0.37 0.33 0.3 0.22 0.16
Electrical Load
Use these factors to determine relative lumen output for
average ambient temperatures from 0-40°C (32-104°F).
Lumen Ambient Temperature
(LAT) Multipliers
Ambient Lumen Multiplier
0°C 32°F 1.07
10°C 50°F 1.04
20°C 68°F 1.02
25°C 77°F 1.00
30°C 86°F 0.98
40°C 104°F 0.95
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for
the DSXF LED 4 A530 platform based on 8400 hours of LED
testing (tested per IESNA LM-80-08 and projected per IESNA
TM-21-11).
To calculate LLF, use the lumen maintenance factor that
corresponds to the desired number of operating hours below.
For other lumen maintenance values, contact factory.
Operating Hours 0 25,000 50,000 100,000
Lumen Maintenance
Factor
1.0 0.94 0.90 0.80
DSXF2-LED
Rev. 10/02/14