Technical Specifications

900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com
WARRANTY: Sensor Switch, Inc. warrants these products to be free of defects in manufacture and workmanship for
a period of 60 months. Sensor Switch, Inc., upon prompt notice of such defect, will, at its option, provide a Returned
Material Authorization number and repair or replace returned product.
LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and
implied warranties (including the implied warranties of merchantability and tness for use) and under no circumstances
shall Sensor Switch, Inc. be liable for any incidental or consequential property damages or losses.
TS-CMRB-015A
Revised 07.07.10 © 2010 Sensor Switch
INSTALLATION
WIRING (DO NOT WIRE HOT)
COVERAGE PATTERN
0 ft
9
0 m
2.7
SIDE VIEW
TOP VIEW
12
6
0 ft
6
12
3.7
1.8
0 m
1.8
3.7
12 6 0 ft 6 12
3.7 1.8 0 m 1.8 3.7
9 STANDARD RANGE 360º LENS W/ MICROPHONICS
Best choice for small motion (e.g. hand movements) detection
Viewing angle of 56º in a 360º conical shaped pattern
Provides 12 ft (3.66 m) radial coverage when mounted to standard 9 ft
(2.74 m) ceiling
8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft (3.05 to
6.10 m) radial coverage
Microphonics™ provides overlapping detection of human activity over the
complete PIR coverage area. Advanced ltering is also utilized to prevent
non-occupant noises from keeping the lights on.
PROGRAMMING
Refer to instruction card IC7.001 for default settings and directions on programming the sensor via the push-button.
0 ft
9
0 m
2.7
SIDE VIEW
TOP VIEW
12
6
0 ft
6
12
3.7
1.8
0 m
1.8
3.7
12 6 0 ft 6 12
3.7 1.8 0 m 1.8 3.7
FB3
STANDARD WIRING
BLACK* - Line Input
BLACK* - Load Output
WHITE - Neutral
347 VAC OPTION (347)
Black wires are replaced w/ Red wires
DIMMING OPTIONS (D, ADC)
VIOLET - Connect to Violet control wire from 0-10 VDC
dimmable ballast
GRAY - Connect to Gray common wire from ballast
INITIAL POWER UP
The sensor’s relay is shipped in a latched closed position so the lights
will come on upon initial power-up. If the lights do not immediately turn
on (initial installation only) the latching relay opened during shipment and
will close within 30 secs.
Note: If the sensor loses power, the internal relay will latch to on.
VIO (+)
GRY (-)
[D, ADC] Automatic Dimming
Control
The Fixture Mount Box enclosure has an extended chase nipple that is used
to mount the sensor through a ½” knockout hole to a xture or junction box.
Sensor will detect motions crossing segments more effectively than motions
parallel to beams.
If the sensor’s eld-of-view is partially blocked by the xture housing, the
FB3 Fixture Bracket (not included) can be used to lower the sensor down to
a level where its view is not impaired.
PUSH BUTTON
LOCK NUTCHASE NIPPLE KNOCK OUT
*BLACK wires can be reversed
}