Specification
Page 14 of 14
CLX
INDUSTRIAL: One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.lithonia.com © 2017-2021 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/05/21
CLX LED Linear
Compatible RELOC® Cables for Industrial Luminaires (ordered and shipped separately)
OCS OCU
DC PT
OD
Series Wiring instructions
RRL RELOC®-ready luminaire A Hot conductor wired to position #1 (phase A)
B Hot conductor wired to position #2 (phase B)
C Hot conductor wired to position #3 (phase C)
1
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: RRLA
Notes
1 C, ABE, and C12S options are not used with Quick-Flex QFC, QSFC, QPT, and QD.
RRL RELOC®-Ready Luminaire
• RRL connectors can be used with Quick-Flex®, System 820 and OnePass® systems.
• Load side of connector factory installed to luminaire.
• 4-pole mating connector with push-in terminations allows for simple installation.
• Touch-safe design on both halves meets UL/CSA requirement.
• Wiping contact design allows safe disconnect under load.
PRODUCT INFORMATION
Advanced plug-in system with two-circuit capability. Available on industrial and strip products and a variety of architectural
products mounted in continuous rows. 1, 2, 3 and 4-lamp fixtures. PLR22 (2-circuit) and crossover harness switches hot circuit
serving next fixture in row. Reduces fixture types on job for alternating circuit applications (see example below.)
Easy one-step installation, saves up to 35% on labor costs. Expanded switching flexibility helps save energy.
Rows can be 50% longer with two-circuit systems. Polarized, lock-together nylon connectors prevent miswiring in the field. #12
THHN conductor, rated 600V, 90°C. White neutral wire included. Grounding accomplished by fixture in-row connectors.
CSA certified systems available with up to 2 circuits. G ground required.
Note: Specifications subject to change without notice.
Wiring
PLR
Advanced 1 or 2-Circuit Plug-In
Typical Applications
• Multiple-circuit and single-circuit for longer continuous rows
• Multiple-circuit with alternating fixtures on separate circuits and 2-circuit (PLR 22)
• Multiple circuit with night-lights located along row as desired
Series Number of hot wires Branch circuits Dimming Ground
PLR
PLR22
(blank) Not required for 22
1 Black
2 Black and red
Circuits to which ballast is connected
(blank) Not required for 22
A Black wire
B Red wire
Emergency circuit connected
(blank) No emergency circuit
ELA Emergency circuit wired to black wire
ELB Emergency circuit wired to red wire
LV Low-voltage
dimming
G Ground
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.