Installation Guide

Page 9 of 14
U351 Rev. J 03/10/2020
LED IMPORTANT SAFETY INSTRUCTIONS
Section F: Wiring Emergency (BGTD, PS1055, E10WLCP)
1) Install fixture with mounting brackets, directly to surface, or with V-hooks. Do not wire.
2) The emergency battery pack indicator light needs to be plugged in during installaion. Remove housing end cap near access plate
as shown in previous instructions.
3) For the emergency battery pack the fixture will be provided with a wiring harness at the access plate end. Attach the two
connectors together to activate the battery pack
4) Connect unswitching power to unswitched fixture wire. Connect switched power to white, black, and green wires. Supply wire
must meet applicable electrical codes and be rated for a minimum of 90⁰C. Purple and gray leads are 0-10V (low voltage) dimming
leads.
Worst case maximum mounting height
CLX FDL WD 30K 90CRI
21 FT
SECTION G: nLight AIR Commissioning (NLTAIR2 RES7, NLTAIR2 RES7PDT, NLTAIR2 RIO)
Out of the Box Sensors perform as follows:
100% Light Output for 7.5 minutes, then 1% light output for 2.5minutes before turning off.
1) Please refer to nLight AIR Quick Start Guide (912-00058-001) included with the luminaire.
2) Please locate additional references and resources below:
http://www.acuitybrands.com/clx http://www.acuitybrands.com/nlightair