Cut Sheet
C General-Purpose Strip
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. All data based on 25°C. Full
photometric data on these and other configurations available upon request.
Sheet #: C
Lithonia Lighting
Fluorescent
One Lithonia Way, Conyers, GA 30012
Phone: 770-922-9000, 800-315-4963, Fax: 770-602-1531
www.lithonia.com
MOUNTING DATA
For unit or row installation, surface or suspended mounting.
Unit installation — Minimum of two hangers required.
Row installation — Two hangers per channel required. One per
fixture plus one per row if CONLGC installed.
Hooker
®
(HRC) and HC Hangers — Minimum two per channel
(unit and row)
See ACCESSORIES below for hanging devices.
DIMENSIONS
Inches (millimeters). Subject to change without notice.
48", 72" and 96" have only two 7/8" K.O.'s 6" from each end
24" and 36" have only two 7/8" K.O.'s 3-1/4" from each end
D = 11/16 (17) Dia.K.O.
E = 7/8 (22) Dia.K.O.
F = 1-1/4 (32) Dia.K.O.
H = 2 (51) Dia.K.O.
Energy (Calculated in accordance with NEMA standard LE-5)
ANNUAL LAMP LAMP BALLAST
LER.FL ENERGY COST* DESCRIPTION LUMENS FACTOR WATTS
86.2 $2.79 (2)T8 F32 2900 .88 55
* Comparative yearly lighting energy cost per 1000 lumens
©1996-2010 Acuity Brands Lighting, Inc. All rights reserved. Rev. 1/13/10
Coefficients of Utilization
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
RCR
0
1
2
3
4
5
6
7
8
9
10
103
86
74
64
56
49
44
40
36
33
30
103
82
67
56
47
41
36
32
28
25
23
103
78
61
49
41
35
30
26
23
20
18
98
82
70
61
53
47
42
38
35
32
29
98
78
64
54
46
39
34
30
27
25
22
98
74
59
48
40
34
29
25
22
20
18
90
75
64
56
49
43
39
35
32
29
27
90
72
59
49
42
37
32
28
25
23
21
90
69
55
44
37
31
27
24
21
19
17
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1785.8
3042.4
5944.0
9027.5
2341.8
11369.4
14.2
24.1
47.2
71.6
18.6
90.2
15.7
26.8
52.3
79.4
20.6
100.0
TEST NO: LTL 18310
C 2 96
LUMENS PER LAMP: 6300
Coefficients of Utilization
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
RCR
0
1
2
3
4
5
6
7
8
9
10
106
89
76
65
57
51
45
41
37
34
31
106
84
68
57
48
42
36
32
29
26
23
106
79
62
50
42
35
30
26
23
20
18
102
85
72
62
55
48
43
39
35
32
30
102
80
66
55
47
40
35
31
28
25
23
102
76
60
49
40
34
29
25
22
20
18
93
78
66
57
50
44
40
36
33
30
28
93
74
61
51
43
37
33
29
26
23
21
93
71
56
45
38
32
28
24
21
19
17
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
842.1
1435.8
2810.1
4362.5
1021.0
5383.6
14.5
24.8
48.4
75.2
17.6
92.8
15.6
26.7
52.2
81.0
19.0
100.0
TEST NO: LTL 5181
C 2 32
LUMENS PER LAMP: 2900
Energy (Calculated in accordance with NEMA standard LE-5)
ORDERING
ANNUAL LAMP LAMP BALLAST
INFORMATION LER.FL ENERGY COST* DESCRIPTION LUMENS FACTOR WATTS
C 2 32 MVOLT GEB10IS 77.6 $3.09 F32T8/735 2800 .88 59
C 2 32 MVOLT BILP 93.6 $2.56 F32T8/835/HT8 3100 .78 48
* Comparative yearly lighting energy cost per 1000 lumens