Cut Sheet

6B1 6" Premium Baffle Full Reflector Trim
Distribution curve Distribution data Output data Coefficient of utilization Single luminaire data 30" above floor
6B1, 75W A19 lamp, 1.3 s/mh, 1210 rated lumens, test no. 2194040604
90°
rf 20%
rc
80% 70% 50%
rw 50% 30% 50% 30% 50% 30%
1323132313030
2292829282827
3272526252624
4252324222422
5222022202120
6201820182018
7181618161816
8171516141614
9151315131513
10 14 12 14 12 13 11
25
50
75
100
125
90°
6B1, 13W F13DTT/27K lamp, 1.5 s/mh, 900 rated lumens, test no. 2194061712
rf 20%
rc
80% 70% 50%
rw 50% 30% 50% 30% 50% 30%
1353535 343333
23331 32 313130
33028 30 282927
42826 27 262725
52623 25 232523
62321 23 212321
72119 21 192119
82018 19 171917
91816 18 161816
10 17 14 16 14 16 14
From 0° cp. Lumens
101
103 10
15° 113 32
25° 124 56
35° 108 67
45° 71 55
55° 36 32
65° 9 10
75° 0 0
85° 0 0
90° 0
Zone Lumens %lamp
0°-30° 98 10.9
0°-40° 165 18.4
0°-60° 253 28.1
0°-90° 263 29.2
90°-180° 0 0.0
0°-180° 263 29.2*
* Efficiency
50% 10%
Beam angle 74.6° Beam angle 104.7°
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 3.4 8.4' 1.7 14.3' 0.3
10' 1.8 11.4' 0.9 19.5' 0.2
12' 1.1 14.5' 0.6 24.6' 0.1
14' .8 17.5' 0.4 29.8' 0.1
16' .6 20.6' 0.3 35.0' 0.1
Zone Lumens %lamp
0°-30° 170 14.1
0°-40° 271 22.4
0°-60° 380 31.4
0°-90° 389 32.2
90°-180° 0 0.0
0°-180° 389 32.2*
* Efficiency
From 0° cp. Lumens
215
214 20
15° 208 59
25° 199 91
35° 163 101
45° 93 73
55° 39 36
65° 7 9
75° 0 0
85° 0 0
90° 0
50% 10%
Beam angle 64.1° Beam angle 96.4°
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 7.1 6.9' 3.6 12.3' 0.7
10' 3.8 9.4' 1.9 16.8' 0.4
12' 2.4 11.9' 1.2 21.2' 0.2
14' 1.6 14.4' 0.8 25.7' 0.2
16' 1.2 16.9' 0.6 30.2' 0.1
44
88
132
176
220
45°
45°
To calculate light levels for other lamps, multiply the footcandle levels by
the ratio of desired-lamp lumens to displayed-lamp lumens.
Example: fc level at nadir for 100W A19 is 19. With a 75W A19,
fc level is 19 x (1,210/1,750) or 13 fc.
Incandescent Compact Fluorescent
Lamp Lumens Lamp Lumens
150W A21 2,850 26W DTT 1,800
100W A19 1,750 18W DTT 1,250
75W A19 1,210 13W DTT 860
60W A19 870 9W DTT 575
40W A19 460
Consult chart on page LAMP for appropriate R or PAR lamp data.
Conversion Factor
Use multiplier to determine candlepower,
lumens and footcandles of other finishes.
Gold = .9; Black = .85; White Baffle = 1.1.
ELECTRICAL CHARACTERISTICS
120 Volt HPF 277 Volt HPF 347 Volt HPF
Maximum Input Maximum Input Maximum Input
Lamp current watts current watts current watts
(1) 9TT 0.140 11.0 0.170 14.0 0.190 15.0
(2) 9TT 0.280 22.0 0.340 28.0 0.380 30.0
(1) 13TT/DTT 0.285 17.0 0.340 22.0 0.330 24.0
(2) 13TT/DTT 0.570 34.0 0.680 44.0 0.660 48.0
Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating
factors can cause differences between laboratory data and actual field measurements. Dimensions and
specifications are based on the most current available data and are subject to change without notice.
Sheet #: 6B1
©2000 Acuity Brands Lighting, Inc., Rev. 05/02/07
Energy (Calculated in accordance with NEMA standard LE-5. )
Fixture/ LER Annual* Lamps Lamp Ballast Input
Reflector Energy Cost Lumens Factor Watts
LP6F DTT/6B1 16.13 $14.88 13W DTT 860 1.0 16
LP6 A19/6B1 5.16 $46.49 75W A19 1210 N/A 75
*Comparative yearly lighting energy cost per 1000 lumens
Lithonia Lighting
Recessed Downlighting
One Lithonia Way, Conyers, GA 30012
Phone: 800-315-4935 Fax: 770-918-1209