Accessories: Order as separate catalog number.
2VT2 F916 Trim to adjust fixture mounting flush with
9/16" T-bar; for 2x2 fixture
DGA22 FS/VT Drywall ceiling adapter with trim kit
Notes
1 Approximate lumen output.
2 Consult factory for availability. Not available with SLD,EL7L or EL14 battery packs.
3 Not available with N80, N80EMG, N100 or N100EMG.
4 Gateway not included. Requires on-site commissioning.
Visit www.lightingcontrols.com/XPointWireless for more information.
5 nLight EMG option requires a connection to existing nLight network. Power is
provided from a separate N80 or N100 enabled fixture.
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: 2VTL2 40L ADPT EZ1 LP840 MSD7ADCX
2VTL2
Series Air function Lumens Diffuser Voltage Driver Color temperature
2VTL2 2X2 VTL (blank) Static
H Heat removal
20L 2000
1
33L 3300
1
40L 4000
1
ADP Acrylic linear prismatic
ADPT Acrylic linear prismatic
with diffuser trim rings
(blank) MVOLT
347 347
2
EZ1 eldoLED dims to 1% (0-10 volt dimming)
EZB eldoLED dims to dark (0-10 volt dimming)
EDB eldoLED DALI
3
EXB eldoLED DMX/RDM
3
SLD Step-level dimming
3
EXA1 Dims to 1%, XPoint wireless enabled
4
EXAB Dims to dark, XPoint wireless enabled
4
LP830 82CRI, 3000 K
LP835 82CRI, 3500 K
LP840 82CRI, 4000 K
LP850 82CRI, 5000 K
Controls Occupancy Control
6
Options
(blank) No nLight
®
N80 nLight
® with 80% lumen
management
N80EMG nLight
®
with 80% lumen
management For use with
generator supply EM power
5
N100 nLight
®
without lumen
management
N100EMG nLight
®
without lumen
management For use with
generator supply EM power
5
(blank) No sensor control
nLight Wired Networking
NES7 nLight™
nES 7 PIR integral occupancy sensor
7
NESPDT7 nLight™ nES PDT 7 dual technology integral
occupancy control
7
NES7ADCX nLight™ nES 7 ADCX PIR integral occupancy sensor
with automatic dimming photocell
7
NESPDT7ADCX nLight™ nES PDT 7 dual technology integral
occupancy sensor with automatic dimming
photocell
7
Xpoint Wireless Networking
XADS7 Xpoint™ micro 360° PIR occupancy
sensor and automatic dimming
photocell
4,8,9
Individual Control
MSD7ADCX PIR integral occupancy sensor
with automatic dimming control
photocell
8,10
MSDPDT7ADCX PDT integral occupancy sensor
with automatic dimming control
photocell
8,10
EL7L 700 lumen
battery pack
EL14L 1400 lumen
battery pack
EL14LSD 1400 lumen
battery pack with
self-diagnostic
testing feature
11
CP Chicago plenum
6 Must specify ADPT diffuser. See sensor section on page 2.
7 Requires N80, N80EMG, N100, or N100EMG.
8 Not available with N80, N80EMG, N100, or N100EMG.
9 Only available with EXA1 or EXAB driver options.
10 Only available with EZ1 driver option. 0-10v dimming wires not
accessible via access plate.
11 For more information, please see the PSSD2 specification sheet.