ORDERING INFORMATION
Example: 2BLT2R 33L ADP EZ1 LP835
2BLT2R
Series Trim Type/ Air Function Lumens
2
Diuser Voltage Driver Color temperature
2BLT2R 2X2
BLTR
(blank) Standard white two-
piece anged bracket
A Standard two-piece
anged bracket painted
black to match parabolic
/ air-handling reveals
F Flangeless two-piece
bracket for installation
in drywall / “hard lid”
ceilings
LPB One-piece low prole
bracket for installation
in some obstructed
housings (consult
factory)
Standard
eciency
(>125 LPW)
20L 2000
33L 3300
40L 4000
High
eciency
(>130 LPW)
20LHE 2000
33LHE 3300
40LHE 4000
48LHE 4800
ADP Curved, linear prisms
ADSM Curved, smooth
SDP Square, linear prisms
SDSM Square, smooth
Diusers w/ trim rings
ADPT Curved, linear prisms
ADSMT Curved, smooth
SDPT Square, linear prisms
SDSMT Square, smooth
(blank) MVOLT
120 120V
277 277V
347 347V
4 ,5
EZ1 eldoLED dims to
1% (0-10 volt
dimming)
GZ1 Dims to 1% (0-10V
dimming)
6
GZ10 Dims to 10% (0-
10V dimming)
6
SLD Step-level
dimming
7
EOHN On/O (non-dim)
LP830 82CRI, 3000 K
LP835 82CRI, 3500 K
LP840 82CRI, 4000 K
LP850 82CRI, 5000 K
LP930 90CRI, 3000K
LP935 90CRI, 3500K
LP940 90CRI, 4000K
LP950 90CRI, 5000K
nLight Interface Control
10
Standby Mode Options
nLight Wired
(blank) no nLight ® interface
N80
nLight with 80% lumen
management
N80EMG nLight with 80% lumen
management. For use
with generator supply
EM power
8
N100 nLight without lumen
management
N100EMG nLight without lumen
management. For use
with generator supply
EM power
8
nLight Wireless
(blank) no nLight ® interface
NLTAIR2
nLight AIR Generation 2
enabled
9
nLight Wired
(blank) No sensor control
NES7
nLight™ nES 7 PIR integral occupancy sensor
11
NESPDT7
nLight™ nES PDT 7 dual technology integral
occupancy control
11
NES7ADCX
nLight™ nES 7 ADCX PIR integral occupancy
sensor with automatic dimming photocell
11
NESPDT7ADCX
nLight™ nES PDT 7 dual technology integral
occupancy sensor with automatic dimming
photocell
11
nLight Wireless
RES7 nLight AIR control with PIR integral occupancy
sensor and automatic dimming photocell
RES7PDT nLight AIR control with PDT dual technology
integral occupancy sensor and automatic
dimming photocell
RIO nLight AIR radio module without sensor
RES7EM nLight AIR PIR integral occupancy sensor with
automatic dimming photocell and UL924
Emergency Operation, via power interrupt
detection
17
RES7PDTEM nLight AIR microphonics dual technology
occupancy sensor with automatic dimming
photocell and UL924 Emergency Operation, via
power interrupt detection
17
RIOEM nLight AIR radio module less sensor, with
UL924 Emergency Operation, via power
interrupt detection
17
Individual Control
MSD7ADCX PIR integral
occupancy sensor
with automatic
dimming control
photocell
12
MSDPDT7ADCX PDT integral
occupancy sensor
with automatic
dimming control
photocell
12
JOT Wireless room control
with “Just One Touch”
pairing
18
JOTVTX15 Wireless occupancy
sensor with “Just One
Touch” pairing
18
NOC Occupancy
sensor
disabled
13
EL7L 700 lumen battery pack
EL14L 1400 lumen battery pack
E10WLCP EM Self-Diagnostic
battery pack, 10W
Constant Power, Certied
in CA Title 20 MAEDBS
BGTD Bodine Generator Transfer
Device
14
GLR Fast-blowing fuse
15
GMF Slow-blowing fuse
15
NPLT Narrow pallet
FAO Field adjustable output
16
BAA Buy America(n) Act
Compliant
JP32 Job Pack
A+ Capable options indicated
by this color background.
Notes
1 Consult factory for airflow data.
2 Approximate lumen output.
3 All versions may not achieve 130+ LPW. Refer to
photometry on www.acuitybrands.com.
4 Not available with EL7L or EL14L battery packs.
5 347 not available with SLD
6 GZ1, GZ10 not available with any Control or Sensor options.
7 Not available with N80, N80EMG, N100, N100EMG, NLTAIR2,
or occupancy control.
8 nLight EMG option requires a connection to existing nLight
network. Power is provided from a separate N80 or N100
enabled fixture.
9 Must order with RES7, RES7PDT, or RIO sensor. Only
available with EZ1 driver.
10 Must specify diffuser with trim rings. See sensor options
on page 4.
11 Requires N80, N80EMG, N100, or N100EMG.
12 Only available with EZ1 driver option. 0-10v dimming wires
not accessible via access plate. Not available with Controls
options.
13 Can only be ordered in conjunction with EZ1, NLTAIR2,
RES7/RES7PDT. Occupancy sensor disabled at factory but
can be re-enabled upon commissioning.
14 Requires BSE labeling. Consult factory for options.
15 Must specify voltage, 120 or 277 with GLR & GMF fusing.
16 Consult factory.
17 See UL924 Sequence of Operation chart on page 3.
18 Wired 0-10v dimming control not available. Not available
with nLight Interface or Controls options. Not available
with SLD, NOC, BGTD, or FAO. Must specify diffuser with
trim rings.
Lead times will vary depending on options selected. Consult with your sales representative.