Installation Manual

TROUBLESHOOTING
REASON CAUSE REMEDY
The load will not
illuminate
Incorrect daylight sensor setting selected. Adjust setting.
Load had failed. Replace load.
Power is switched off. Switch on.
The load is permanently
illuminated.
Continuous movement in the detection area. Check detection area setting.
The lamp (Containing sensor) is installed in an
area too close to reflective surfaces, i.e. metal,
glass or concrete walls.
Make sure installation area suitable with at least 30
cm space between lamp and surrounding reflective
surfaces.
Reduce sensitivity (Detection are).
The load will not
illuminate despite
movement.
Speed of moving object is not in the range of 0.
5~3m/s or the detection radius is too small.
Check detection area setting.
Stand-by dimming level
Determines the light level you would like to have after the hold time in
the long absence of people.
Daylight sensor
The sensor can be set to only allow the lamp to illuminate below a
defined ambient brightness threshold.
When set to Disable mode, the daylight sensor will switch on the lamp
when motion is detected regardless of ambient light level.
Note that daylight sensor is active only when lamp totally switches off.
ON
10 11 12
I ON ON ON Disable
II ON 200lux
III ON 100lux
IV 50lux
ON
8 9
I ON ON 50%
II ON 30%
III ON 20%
IV 10%
MOTION SENSOR
INSTALLATION