Installation Manual

5
1. Turn o the power to the xture from the circuit breaker.
2. Remove the existing uorescent tubes. Recycle according to
EPA guidelines (EPA.Gov).
3. Open the xture (ballast) cover to expose the ballast and set
cover aside.
4. Disconnect the existing input and output ballast leads
by cutting close to the ballast enclosure and remove the
leads (black and white wires). Lampholders may remain in
place but the leads to the lampholders should be cut at the
lamp holder.
RF16UQT1XXC, RF32UQT1XXC, RF45UQT1XXC
4 & 8 STRIP FIXTURE INSTALL
1. Retrot must be installed to a grounded luminaire.
2. 1x4 strip install does not require the use of a junction box.
3. Ballast cover should be mechanically secured to physically support the Retrot.
1x4 Strip Fixture with T8 Tubes 1x4 Strip Fixture with LED Retrot
Before After
Section 1