Installation Manual
2
CRITICAL SAFETY INSTRUCTIONS: Installation should only be conducted by a qualied electrician in accordance with NEC and any relevant
local building codes.
LED RETROFIT WARNINGS: Risk of re or electric shock. LED RetroFit kit installation requires knowledge of luminaires electrical system. If not
qualied, do not attempt installation. Contact a qualied electrician. Luminaire wiring and electrical parts may be damaged when drilling for installation
of LED RetroFit kit. Check for enclosed wiring and components. Do not make or alter any open holes in the enclosure of wiring or electrical components
during kit installation. If Installing 4’ or 8’ strip xture insure width is greater or equal to 2”.
WARNING: Risk of re or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photo
-
graphs and/or drawings and where the input rating of the retrot kit does not exceed the input rating of the luminaire. Only those open holdes indicated
in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or
electrical components.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
This LED RetroFit Kit and Junction Box Cover shall only be installed into a UL/CUL listed luminaire with a steel enclosure. DO NOT INSTALL THIS
RETROFIT KIT INTO LUMINAIRES WITH NON-FERROUS METAL OR POLYMERIC ENCLOSURES
Do not use with dimmers.
DISCONNECT SAFETY INSTRUCTIONS:
WARNING - This is a current rated device. Use in applications involving amperage beyond its rating can be dangerous and cause electrical res. See
note on this page for allowable current and voltage levels and do not exceed those levels.
DANGER - NEVER remove wires from product as contact with electricity can cause serious injury or death. Shut off power at the circuit breaker or
remove fuse when installing this product.
SAFETY NOTICE - Improperly installed electrical wiring can be dangerous and cause electrical res. This product must be used in accordance with
the current rating and wire sizes listed.
COPPER to COPPER ONLY. Do not use on Aluminum. Temperature rating: 105° C (221° F) maximum. Flame Rated UL94V-0.
This product is intended for use in a UL/C-UL listed Fluorescent Recessed or surface-mounted luminaire, Type IC or Non-IC, with the dimensions
specied.
Section 1- 4’ OR 8’ STRIP FIXTURE INSTALL 5
Section 2- HARDWIRE STRIP FIXTURE INSTALL 10
Section 3- TROFFER OR WRAP INSTALL 15
Section 4- STANDALONE USE 19
INTRODUCTION & TABLE OF CONTENTS
SAFETY INSTRUCTIONS AND WARNINGS
INCLUDED CN-02 CONNECTOR FOR RETROFIT POWER
Congratulations on the purchase of your 1x4 Retrot. It is usable for a range of installations. Some of the
most popular ones are included here.
Hot
Neutral
Line Side (4 ports)