User's Manual

User Manual Rev 1.11
Basic/Smart/Smart Plus/Intelligent Charger-32A
70
4.3.2 RFID card (for SC3+/IC3 only)
1. Insert the charging plug into the EV
2. Swipe card
3. Waiting for authorizing
4. Charging session started
Stop charging
1. Unplug any time (disconnect the charging plug from EV to stop charging session)
2. Session ended (please return the connector to the holster)
4.4.1 Interrupt charging
Please refer to STOP CHARGING section for more information.
4.4.2 Auto restart
When a charging session is interrupted due to a temporary error condition, the charge point will
automatically restart charging when the cause of the temporary error condition returns to normal.
Status indicator lights remain flashing RED until the error condition is resolved.
Temporary error conditions include: Over Current, Over Voltage, Under Voltage, and Over
Temperature.
For Over Current conditions: The charging session will be stop while OC occurs. After recovery from
OC for 30 seconds, the charge point will automatically restart charging for three times.
When charging session stopped due to CCID trip, the charge point will try to restart after 15 minutes
for 3 times.
4.4.3 Power outage recovery
When power resumes after an outage, the charge point restarts automatically with a delay ranging from
120 to 720 seconds. The delay is designed to avoid impacting the utility grid when multiple charge points
are in the same area attempting to resume charging simultaneously.