User's Manual
User Manual Rev 1.11
Basic/Smart/Smart Plus/Intelligent Charger-32A
57
HINT: If user changes “Network Mode” setting, then related settings will also change automatically such
as “Connectivity”, “Local Load Management”. The default value is as follow:
Direct
Gateway
Client
Gateway LAN IP
Not used
Default value, not changeable
Not used
Gateway LAN Port
Not used
Default value, not changeable
Not used
Max Group Number
Not used
Default value, not changeable
Not used
Group Use External Gateway
Not used
Yes or No
Yes or No
Gateway Serial Number
Not used
Not used
Used
Connectivity
Auto
Wi-Fi or Cellular
Wi-Fi, not changeable
Local Load Management
Disable, not
changeable
Enable
Enable
Charging Policy – The charging policy for LLM Gateway to decide the charging current for each charge
point. Valid options are:
1) UD (default): Uniform Distribution. The maximum amperage is divided by total numbers of
charging EV, i.e. each EV will use the same charging current.
2) FIFS: First In First Serve.
Group ID – An identity of the LLM group. A slave with different group identity will be rejected when
attempting to connect to Gateway.
Group Size – The total number of charge points in the LLM group. This value is only used in Gateway.
Max Amperage Grid Connection – Total ampere of each phase allowed loading for the group of charge
points at the same time. This value is only used in Gateway.
Fallback Current – The fallback current when Client is not able to communicate with Gateway. Gateway
will overwrite fallback current in Client with its own value when Client connected to Gateway.