Gateway LAN IP The IP of master in LAN. This value cannot be modified by users.
Gateway LAN Port (SOAP) The listen port for OCPP SOAP client server. This value cannot be modified
by users.
Max Group Size The maximum number of charge points allowed in a group/LAN. This value cannot be
modified by users.
Gateway Serial Number The serial number of the charge point which acts as a Gateway.
Group Use External Gateway Gateway/Client mode use external gateway as a local network group or
not (use Gateway IC3).
Hide AP SSID Options for hiding SSID of this charge point or not. For our product this option is always
off.
Connectivity Specifies whether the charge point should always be connected to Internet using None,
Auto, Wi-Fi, or Cellular. Default value is Auto. [Cellular: IC3 support only] When Network Mode is
Direct, all option are available. If it is not, then Connectivity will be set with the following rule:
Network Mode
Group Use External Gateway = Yes
Group Use External Gateway = No
Gateway
Wi-Fi
Cellular
Client
Wi-Fi
Wi-Fi setting will be disabled and
Client will setup Wi-Fi to connect to
Wi-Fi
NOTE
A Gateway charge point can choose using Wi-Fi or Cellular to connect to the internet by change
'Group Use External Gateway' setting. If set to Yes, a Gateway will use Cellular, or it will use Wi-Fi.
When changed this setting, the 'Connectivity' option will automatically change as well.
All charge point in this Gateway/Client group must have the same 'Group Use External Gateway'
setting, i.e. all charge points must set this option to Yes (including Gateway and Client) when we
want to use an external Wi-Fi AP to connect to internet. In this case, all charge points must also