User's Manual

User Manual Rev 1.11
Basic/Smart/Smart Plus/Intelligent Charger-32A
48
HeartBeatInterval Defines the heartbeat interval.
LightIntensity Percentage of maximum intensity at which to illuminate the charge point lighting. This
value is not changeable for our product.
LocalAuthorizeOffline Whether the charge point, when offline, will start a transaction for locally-
authorizedidentifiers.
LocalPreAuthorize Whether the charge point, when online, will start a transaction for locally
authorized identifiers without waiting for or requesting an Authorize.conf from Central System.
MaxEnergyOnInvalidId Maximum energy in Watt-hour (Wh) delivered when an identifier is
invalidated by Central System after start of a transaction.
MeterValuesAlignedData Clock-aligned measurand(s) to be included in a MeterValues.req PDU, every
ClockAlignedDataInterval seconds. Supported value are Current.Import, Energy.Active.Import.Register,
and Temperature, Voltage or any combination of these 4 value.
MeterValuesAlignedDataMaxLength Maximum number of items in a MeterValuesAlignedData
configuration key.
MeterValuesSampledData Sampled measurands to be included in a MeterValues.req PDU, every
MeterValueSampleInterval seconds. Supported value are Current.Import, Energy.Active.Import.Register,
and Temperature, Voltage or any combination of these 4 value.
MeterValuesSampledDataMaxLength Maximum number of items in a MeterValuesSampledData
configuration key.
MeterValueSampleInterval Interval between sampling of metering (or other) data, intended to be
transmitted by "MeterValues" PDUs
MinimumStatusDuration The minimum duration that a charge point or connector status is stable
before a StatusNotification.req PDU is sent to Central System.
NumberOfConnectors The number of physical charging connectors of this charge point.
ResetRetries Number of times to retry an unsuccessful reset of the charge point.
ConnectorPhaseRotation The phase rotation per connector in respect to the connector’s energy
meter. This is not supported by our product since it is single phase power input and the value will always
be NotApplicable.