User's Manual

User Manual Rev 1.11
Basic/Smart/Smart Plus/Intelligent Charger-32A
47
OCPP1.6 Settings
These settings are defined and request for support in OCPP 1.6 sepcification.
AllowOfflineTxForUnknownId If set to yes, an unknown ID (not in Authorization and Cache List) will be
accepted and start the charging session when charge point is not connected to central system.
AuthorizationCacheEnabled Charge point supports an Authorization Cache or not.
AuthorizeRemoteTxRequests Whether a remote request to start a transaction in the form of a
RemoteStartTransaction.req message should be authorized beforehand like a local action to start a
transaction.
BlinkRepeat Number of times to blink the charge point lighting when signaling. This value is not
changeable for our product.
ClockAlignedDataInterval Size (in seconds) of the clock-aligned data interval. This is the size (in
seconds) of the set of evenly spaced aggregation intervals per day, starting at 00:00:00 (midnight).
ConnectionTimeOut Interval until incipient charging session is automatically canceled due to failure of
EV user to insert the charging cable connector(s) into the appropriate connector(s).
GetConfigurationMaxKeys Maximum number of requested configuration keys in a
GetConfiguration.req PDU.