Charge Point ID – The identity of the charge point as known in the OCPP Central System.
Protocol Name – The name and version of OCPP is running in the charge point.
Central System URL – The URL of the OCPP v1.6 Central System service.
Basic Auth ID – The ID for BASIC authentication in HTTPS (SSL/TLS) connections.
Basic Auth Password – The password for BASIC authentication in HTTPS (SSL/TLS) connections.
FTP Server Username – The username of the FTP Server for OCPP to download firmware files and
upload diagnostic file.
FTP Server Password – The password of the FTP Server for OCPP to download firmware files and upload
diagnostic file.
Message Transport Layer – Select the transport layer of the OCPP service that will be used. For
Intelligent Charger-32A, the available option is WS and WSS.
WS: Connection from charge point to OCPP Server uses WebSocket protocol.
WSS: Connection from charge point to OCPP Server uses Secure WebSocket protocol.
Boot Notification Interval – Interval of re-sending BootNotification.req if not accepted by Central
System.
Boot Notification Retries – Number of times to retry sending BootNotification.req.
“-1” means unlimited
“0” means don’t retry.
PDU Timeout – Interval until the charge point stop waiting for a PDU response.
Download Firmware Interval – Interval of downloading firmware from Central System.
Download Firmware Retries – Number of times to retry downloading firmware.
Upload Diagnostics Interval – Interval of uploading diagnostic file to Central System.
Upload Diagnostics Retries – Number of times to retry uploading diagnostic file.