Plug and Charge ID – If the value is present, the charge point needs to support plug and charge scenario
by using the specific identifier. If absent, authorization for each session is required. This ID must be 8 or
more characters.
Reservation Supported – If true, the charge point will support reservation related messages from
Central System.
Resume Charge After Reboot – Indicate if the charge point resumes charging after power recycle. If
true, the charge point will resume charging according to UL regulations. If false, the charge point will not
resume charging.
RFID Reader –Indicate if RFID reader is available. [Support only on SC3+/IC3]
Ventilation Required – Indicate if ventilation equipment is required. If set this option to yes, a
ventilation fault will occur when the EV report for need ventilation equipment. Recommend setup value
are shown below according to the place and ventilation equipment available or not.
Place
Ventilation Equipment Available
Ventilation Equipment Not Available
Indoor
No
Yes
Outdoor
No
No
Skip Heartbeat Message – Indicate if Heartbeat message is skipped if any other message is sent
successfully during a heartbeat interval.
Other Information
Last Boot Time – Show last boot time.