User's Manual

User Manual Rev 1.11
Basic/Smart/Smart Plus/Intelligent Charger-32A
43
Voltage Low Value at which the charge point will send an under voltage warning message.
Voltage High Value at which the charge point will send an over voltage warning message.
General Settings
Output Power Type AC or DC output power. In our product, this value is always “AC”.
Power Phase Connected Input power phase connected to the charge point to indicate single phase or
three phases. This value is always “1”.
Max Amperage HW Setting The DIP switches (Hardware) settings to indicate the maximum charging
current.
Max Amperage FW Setting The software settings to indicate the maximum charging current.
PWM Amperage The PWM setting for charging current when the charge point is online. This signal is
to tell EV how much current is allowed to use.
Real Amperage The real-time charging current detected by the charge point.
Cold Load Pickup Max Delay Default cold load pickup delay is 120s ~ 720s. The max value could be
changeable by this property.