Datasheet

LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
Electro-Optical Characteristics at Ta=25°C
Parameter
Symbol
Values Test Condition Unit
Forward Voltage
V
F
Min 3.0
I
F
= 120mA V Typ. 3.2
Max.
3.6
Luminous Flux
1
Φ
v
Min 33.5
I
F
= 120mA lm Typ. 42.0
Max.
50.5
Reverse Current
I
R
Max.
100
V
R
= 5V µA
Viewing Angle
2θ
1/2
Typ. 120 I
F
= 120mA
°
Chromaticity Coordinates
x
Typ. 0.329
I
F
= 120mA
y
Typ. 0.342
Optical Efficiency
η
opt
Typ. 109 I
F
= 120mA
lm/W
Correlated Color
Temperature
CCT
Typ. 5700 I
F
= 120mA K
Color Rendering Index CRI
Min 80 I
F
= 120mA
Notes
1. Luminous flux is the total luminous flux output as measured with an integrating sphere.
2. Iv (flux Φ
v
) classification code is marked on each packing bag.
3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram.
4. Caution in ESD:
Static Electricity and surge damages the LED. It is recommended using a wrist band or anti-electrostatic
glove when handling the LED. All devices, equipment and machinery must be properly grounded.
5. CAS140B is the test standard for the chromaticity coordinates (x, y) & Φ
ΦΦ
Φ
v
.
6. The chromaticity coordinates (x, y) guarantee should be added +/- 0.01 tolerance
7. CRI measurement allowance is ±5
Part No. : LTW-Z5630SZL57 Page : 3 of 11
BNS-OD-C131/A4