Datasheet
LITE-ON TECHNOLOGY CORPORATION
Pr o p e r t y o f L i t e - O n O n ly
Electrical Optical Characteristics At Ta=25
℃
Parameter
Symbol
Part No.
LTW-
Min.
Typ.
Max.
Unit
Test Condition
Luminous Intensity
I
V
E670DS
1400
2240
3550
mcd
I
F
= 30mA
Note 1, 2, 5
Luminous Flux
V
E670DS
5200
mlm
I
F
= 30mA
Note 1, 2, 5
Viewing Angle
2
θ
1/2
E670DS
120
deg
Fig.6
Chromaticity Coordinates
x
E670DS
0.32
I
F
= 30mA
Note 3, 5
Fig.1
y
0.31
Forward Voltage
V
F
E670DS
3.6
4.0
V
I
F
= 30mA
Reverse Current
I
R
E670DS
10
μA
V
R
= 5V
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. Iv classification code is marked on each packing bag.
3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram.
4. Caution in ESD:
Static Electricity and surge damages the LED. It is recommended using a wrist band or anti-electrostatic
glove when handling the LED. All devices, equipment and machinery must be properly grounded.
5. The chromaticity coordinates (x, y) guarantee should be added ± 0.02 tolerance.
Part No. : LTW-E670DS
Page : 3 of 11
BNS-OD-C131/A4