Electrical Optical Characteristics At Ta=25
℃
Parameter
Symbol
Part No.
LTW-
Min.
Typ.
Max.
Unit
Test Condition
Luminous Intensity
I
V
670DS
710
1100
1800
mcd
I
F
= 20mA
Note 1, 2, 5
Luminous Flux
V
670DS
2800
mlm
I
F
= 20mA
Note 1, 2, 5
Viewing Angle
2
θ
1/2
670DS
120
deg
Fig.6
Chromaticity Coordinates
x
670DS
0.31
I
F
= 20mA
Note 3, 5
Fig.1
y
0.30
Forward Voltage
V
F
670DS
3.0
3.5
3.7
V
I
F
= 20mA
Reverse Current
I
R
670DS
10
μA
V
R
= 5V
Note : 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. Iv classification code is marked on each packing bag.
3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram.
4. Caution in ESD:
Static Electricity and surge damages the LED. It is recommended using a wrist band or anti-electrostatic
glove when handling the LED. All devices, equipment and machinery must be properly grounded.
5. CAS140B is the test standard for the chromaticity coordinates (x, y) & IV.
Part No. : LTW-670DS
Page : 3 of 11
BNS-OD-C131/A4