Datasheet
LITE-ON TECHNOLOGY CORPORATION
Pr o p e r t y o f L i t e -O n O n l y
Electrical Optical Characteristics At Ta=25
℃
℃℃
℃
Parameter Symbol
Part No.
LTW-
Min. Typ. Max. Unit Test Condition
Luminous Intensity IV 006DCG-E2 1800 2400 mcd
IF = 20mA
Note 1, 2, 5
Viewing Angle
2
θ
1/2
006DCG-E2 110 deg
Fig.6
x 0.277
Chromaticity Coordinates
y
006DCG-E2
0.255
IF = 20mA
Note 3, 5
Fig.1
Forward Voltage VF 006DCG-E2 2.9 3.3 V IF = 20mA
ESD-Withstand Voltage ESD 006DCG-E2 200 V HBM
Note : 1. Luminous intensity is measured with a light sensor and filter combination that approximates the
CIE eye-response curve.
2. Iv classification code is marked on each packing bag.
3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram.
4. Caution in ESD:
Static Electricity and surge damages the LED. It is recommend to use a wrist band or
anti-E2lectrostatic glove when handling the LED. All devices, equipment and machinery
must be properly grounded.
5. CAS140B is the test standard for the chromaticity coordinates (x, y) & IV.
6. The chromaticity coordinates (x, y) guarantee should be added +/- 0.007 tolerance.
Part No. : LTW-006DCG-E2 Page : 3 of 11