Datasheet

LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
Electrical / Optical Characteristics at T
A
=25
Parameter Symbol Min. Typ. Max. Unit
Test Condition
Luminous Intensity I
V
50 mcd
I
F
= 2mA
Note 1
Viewing Angle 2θ
1/2
30 deg Note 2 (Fig.5)
Peak Emission Wavelength λ
P
642 nm
Measurement
@Peak (Fig.1)
Dominant Wavelength λ
d
631
nm Note 4
Spectral Line Half-Width ∆λ
20 nm
Forward Voltage V
F
1.8 V I
F
= 2mA
Reverse Current I
R
100 µA V
R
= 5V
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates
the CIE eye-response curve.
2. θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv
classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents
the single wavelength which defines the color of the device.
5. The Iv guarantee should be added ±30%.
Part No. : LTL2R3KRD-EM Page : 3 of 10
BNS-OD-C131/A4