Through Hole Lamp Product Data Sheet LTL2R3KEK Spec No.: DS-20-98-0286 Effective Date: 04/18/2015 Revision: C LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung Ho, New Taipei City 23585, Taiwan, R.O.C. Tel: 886-2-2222-6181 Fax: 886-2-2221-1948 / 886-2-2221-0660 http://www.liteon.
Through Hole Lamp LTL2R3KEK Through Hole Lamp LTL2R3KEK Rev Description By Date Above data for PD and Customer tracking only C Add Bin Table Spec. Jeromy 1/9 04/01/2015 Part No.
Through Hole Lamp LTL2R3KEK 1. Description Through hole LEDs are offered in a variety of packages such as 3mm, 4mm, 5mm, rectangular, and cylinder which are suitable for all applications requiring status indication. Several intensity and viewing angle choices are available in each color for design flexibility. 1. 1. Features High luminous intensity output. Low power consumption. High efficiency. Versatile mounting on P.C. Board or panel. I.C. Compatible/low current requirement.
Through Hole Lamp LTL2R3KEK 3. Absolute Maximum Ratings at TA=25°C Parameter Maximum Rating Unit 75 mW (1/10 Duty Cycle, 0.1ms Pulse Width) 90 mA DC Forward Current 30 mA Derating Linear From 50°C 0.4 mA/°C Power Dissipation Peak Forward Current Operating Temperature Range -40°C to + 100°C Storage Temperature Range -55°C to + 100°C Lead Soldering Temperature [2.0mm(.0787") From Body] 260°C for 5 Seconds Max. 4. Electrical / Optical Characteristics at TA=25°C Parameter Symbol Min.
Through Hole Lamp LTL2R3KEK 5. Typical Electrical / Optical Characteristics Curves (25°C Ambient Temperature Unless Otherwise Noted) 4/9 Part No.
Through Hole Lamp LTL2R3KEK 6. Packing Spec. 1000, 500 or 200,100 pcs per packing bag 10 packing bags per Inner carton Total 10,000 pcs per Inner carton 8 inner cartons per outer carton Total 80,000 pcs per outer carton In every shipping lot, only the last pack will be non-full packing 5/9 Part No.
Through Hole Lamp LTL2R3KEK 7. Bin Table Specification Luminous Intensity Unit : mcd @20mA Bin Code Min. Max. J 240 310 K 310 400 L 400 520 M 520 680 N 680 880 P 880 1150 Note: Tolerance of each bin limit is ±15% Dominant Wavelength Unit : nm @20mA Bin Code Min Max H28 617.0 621.0 H29 621.0 625.0 H30 625.0 629.0 H31 629.0 633.0 Note: Tolerance of each bin limit is ±1nm 6/9 Part No.
Through Hole Lamp LTL2R3KEK 8. CAUTIONS 8.1. Application This LED lamp is good for application of indoor and outdoor sign, also ordinary electronic equipment. 8.2. Storage The storage ambient for the LEDs should not exceed 30°C temperature or 70% relative humidity. It is recommended that LEDs out of their original packaging are used within three months.
Through Hole Lamp LTL2R3KEK 8.7. ESD (Electrostatic Discharge) Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage: Use a conductive wrist band or anti- electrostatic glove when handling these LEDs All devices, equipment, and machinery must be properly grounded Work tables, storage racks, etc.
Through Hole Lamp LTL2R3KEK 9.