Datasheet

LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
Electrical / Optical Characteristics at T
A
=25
Parameter
Symbol
Min.
Typ.
Max.
Unit
Test Condition
Luminous Intensity
I
V
680
2500
mcd
I
F
= 20mA
Note 1
Viewing Angle
1/2
15
deg
Note 2 (Fig.5)
Peak Emission Wavelength
λ
P
591
nm
Measurement
@Peak (Fig.1)
Dominant Wavelength
λ
d
590
nm
Note 4
Spectral Line Half-Width
Δλ
15
nm
Forward Voltage
V
F
2.05
2.4
V
I
F
= 20mA
Reverse Current
I
R
100
μA
V
R
= 5V
Capacitance
C
40
pF
V
F
= 0 , f = 1MHz
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates
the CIE eye-response curve.
2. θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv
classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents
the single wavelength which defines the color of the device.
5. The Iv guarantee should be added ±15%.
Part No. : LTL2H3KSK
Page : 3 of 10