Datasheet
L I T E - O N E L E C T R O N I C S , I N C .
P r o p e r t y o f L i t e - O n O n l y
Electrical / Optical Characteristics at T
A
=25
℃
Parameter
Symbol
Color
Min.
Typ.
Max.
Unit
Test Condition
Luminous Intensity
I
V
Red Orange
Green
2.2
2.2
4.8
4.8
mcd
I
F
= 20mA
Note 1,4
Viewing Angle
2
θ
1/2
Red Orange
Green
200
deg
Note 2 (Fig.6)
Peak Emission Wavelength
λ
p
Red Orange
Green
630
565
nm
Measurement
@Peak (Fig.1)
Dominant Wavelength
λ
d
Red Orange
Green
621
569
nm
Note 3
Spectral Line Half-Width
Δλ
Red Orange
Green
40
30
nm
Forward Voltage
V
F
Red Orange
Green
2.0
2.1
2.6
2.6
V
I
F
= 20mA
Reverse Current
I
R
Red Orange
Green
100
μ
A
V
R
= 5V
Capacitance
C
Red Orange
Green
20
35
pF
V
F
= 0 , f = 1MHz
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
2.
θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength,
λ
d
is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. The Iv guarantee should be added
±
15% .
5. Reverse current is controlled by dice source.
Part No. : LTL-14CHJ
Page : 3 of 4