User's Manual

44
Charge on.
Figure 5-4. Place the Charging Plug into the Charger Holster.
5.3.1 Interrupt Charging
Please refer to STOP CHARGING section for more information.
5.3.2 Auto Restart
When a charging session is interrupted due to a temporary error condition, the Blink Charger will automatically
restart charging when the cause of the temporary error condition returns to normal. Status indicator lights remain
ashing RED until the error condition is resolved.
• Temporary error conditions include: Over Current, Over Voltage, Under Voltage, Over Temperature.
• For Over Current conditions: The charging seesion will be stop while OC occurs. After recovery from OC
for 30 seconds, Blink Charger will automatically restart charging for three times.
• When charging session stopped due to CCID trip, Blink Charger will try to restart after 15 minutes for 3
times.
5.3.3 Power Outage Recovery
When power resumes after an outage, the Blink Charger restarts automatically with a delay ranging from 120 to
720 seconds. The delay is designed to avoid impacting the utility grid when multiple chargers are in the same area
attempting to resume charging simultaneously.