User's Manual

24
Charge on.
Max Amperage FW Setting Max Amperage allow base on FW design.
Cold Load Pickup Max
Delay
Default cold load pickup delay is 120s ~ 720s.
The max value could be changeable (between 120 ~ 720) by this
property.
EV Connect Timeout Interval (from successful authorization) until incipient charging session
is automatically cancelled due to failure of EV user to (correctly) insert
the charging cable connector(s) into the appropriate socket(s). Unit in
“seconds”.
Plug And Charge ID If the value is present, Charge Point needs to support plug and charge
scenario by using the specic identier. If absent, authorization for each
session is required.
Ofine Authorization Select if the ofine authorization should be enabled or disabled.
Authorize Timeout Max time interval in seconds between presenting RFID-card and
connecting an EV.
Temperature Low Value in Celsius at which the charger will send a temperature low
warning message.
Temperature High Value in Celsius at which the charger will send a temperature high
warning message.
Voltage Low Value at which the charger will send an under voltage warning
message.
Voltage High Value at which the charger will send an over voltage warning message.
Over Current Value at which the charger will send an over current warning message.
Over Current Retries Denes the over current recovery retry times.