Danish Interpretation Systems User Manual List of Contents List of Contents................................................. 3 Document version.......................................... 3 Important ......................................................... 4 Compliancy ................................................... 4 RP 6004 Repeater...........................................7 General description....................................... 7 Features.......................................................
Danish Interpretation Systems User Manual Important Compliancy exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock. The equipment has been tested and found to comply with the limits of the following standards for digital devices: To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
Danish Interpretation Systems User Manual Description of the DCS 6000 system RS232/RS422 connection on CU 6010 for external operation of the system of a PC or control system such as AMX or Crestron Features The DCS 6000 system has the following main features: • Fully digital • Excellent sound quality • “State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance che
Danish Interpretation Systems User Manual Conference equipment and channel selectors System components The CU 6010 Central Unit supports all available units in the DCS 6000 series: Central equipment CU 6010 EX 6010 PS 6000 RP 6004 AO 6008 JB 6002 JB 6004 Central Unit Extension Power Unit Power Supply Repeater for four chains Audio Output box Junction Box with 2 outputs Junction Box with 4 outputs CS 6032FV/H CM/DM 6010P CM/DM 6020P CM/DM 6070P CM/DM 6090P CM/DM 6060F CM/DM 6510F Interpreter equipme
Danish Interpretation Systems User Manual Operating instructions RP 6004 Repeater Features General description The main features of the RP 6004 Repeater are: The RP 6004 Repeater provides repeater and splitter functionality for the DCS 6000 system. One CU 6010 Central Unit is needed in each DCS 6000 system, however for expansion of the system the RP 6004 Repeater is suitable. The RP 6004 consist of the following main parts: • Repeater board with 4 individual repeated outputs.
Danish Interpretation Systems q User Manual q Power LED Those LED light up when Power is available on the connector next to the LED Incoming data LED Those LED flashes, when the unit receives incoming data from connected units on the connector next to the LED. System design There are no settings to be done on the RP 6004 Repeater. However it is important to observe, that the unit is only repeating one of the chains on the CU 6010 Central Unit.
Danish Interpretation Systems User Manual ‘Loop through’ connector When connecting a number of RP 6004 Repeaters to the CU 6010 an almost unlimited number of RP 6004 can be connected by using the ‘Loop through’ connector. The practical limitation is the maximum cable length in one chain, which is 200 m and supply of power to the RP 6004 repeaters. The following schematic is showing the connections using the ‘Loop through’ connectors.
Danish Interpretation Systems User Manual System Setup General guidelines Connect the RP 6004 to the various units using Cat 5 FTP or STP cables. Please observe the following guide lines: • Maximum cable length in one chain is 200 m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc. • Maximum cable length in one chain when using repeaters is 650 m.
Danish Interpretation Systems User Manual Typical schematics The following schematics are showing various configurations : Large sized conference microphone system Manual 01 18 04466 11
Danish Interpretation Systems User Manual Various configurations with RP 6004 Repeater and PS 6000 Power Supply 12 Manual 01 18 04466
Danish Interpretation Systems User Manual Technical appendix Pair 2: Pair 3: Pair 4: Cabling CAT5 Pin 3 & 6 Pin 4 & 5 Pin 7 & 8 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors. The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA 568-B) have to be followed. It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
Danish Interpretation Systems 14 User Manual Manual 01 18 04466